  • Part No.PR2226
    ManufacturerLUMINIS
    Size194 Kbytes
    Pages4 pages
    DescriptionCeiling mount
    Datasheet Summary with AI

    This is a fascinating and dense technical document detailing options and specifications for Luminis lighting fixtures. Here's a breakdown of the key takeaways, organized by sections and with explanations:

    1. General Information (Top of Document)

    ️· Company Information: Luminis has locations in both the USA (Fort Lauderdale, FL) and Canada (DDO, Quebec). Contact information (phone, fax, website) is provided.
    ️· Revision Date: September 2006, with a revision in February 2007. This indicates the information might be somewhat dated.

    2. Mounting and Accessories (Page 16)

    ️· Focus: This section appears to outline available mounting options and related accessories. It's not detailed enough to fully understand without more context.
    ️· "Summary" Section: The document ends abruptly with "SUMMARY," suggesting a potential incompleteness or a placeholder for further explanation.

    3. Technical Options (Detailed Options – Throughout)

    This is the core of the document and covers a lot of technical specifications. I'll categorize these by type:

    ️· Lamp Options (Implied): While not explicitly stated as "lamp options", references to wattage (26W, 32W, 42W, 57W, 70W, 85W, 120W) strongly suggest different lamp types are available.
    ️· Dual Switching (DS1 and DS2):
    - DS1: Allows individual external control of each lamp in a pair.
    - DS2: Allows external control of lamps in pairs, useful for fixtures with 4 or more lamps. For other lamp groupings, the factory should be consulted.
    - Wattage Combinations: Specific DS options are listed with wattage combinations (e.g., DS1-26, DS2-70, DS1-120).
    - Housing Considerations: DS2 options may require increased ballast housing length and stem size.
    ️· Quartz Lamp Emergency Socket (QS): A dedicated 120V power input for a quartz lamp in an emergency situation. Requires separate wiring and is not compatible with CFL lamps.
    ️· Pulse Start Ballast (PS): Requires a lens enclosure (check for compatibility) or a protected lamp version (contact factory). Add "PS" to the lamp wattage designation.
    ️· Quartz Lamp Emergency Socket (QS): 120V dedicated wiring is included.

    4. Important Notes

    ️· Design Changes: The note at the bottom states that Luminis can change design improvements or discontinue products without prior notice. This is a standard disclaimer in technical documentation.

    Overall Interpretation & Limitations:

    ️· Technical Audience: This is a document intended for lighting professionals, electrical engineers, or those with a good understanding of lighting terminology.
    ️· Specific Product: It appears to be specific to a particular line or model of Luminis fixtures. Without the product name, it's difficult to know exactly which fixtures these options apply to.
    ️· Outdated Information: The 2006/2007 revision date means some options might be discontinued or updated. Always verify availability with Luminis directly.
    ️· Missing Context: The abrupt end with "SUMMARY" suggests the document might be incomplete.

    This is a fascinating and dense technical document detailing options and specifications for Luminis lighting fixtures. Here's a breakdown of the key takeaways, organized by sections and with explanations:

    1. General Information (Top of Document)

    ️· Company Information: Luminis has locations in both the USA (Fort Lauderdale, FL) and Canada (DDO, Quebec). Contact information (phone, fax, website) is provided.
    ️· Revision Date: September 2006, with a revision in February 2007. This indicates the information might be somewhat dated.

    2. Mounting and Accessories (Page 16)

    ️· Focus: This section appears to outline available mounting options and related accessories. It's not detailed enough to fully understand without more context.
    ️· "Summary" Section: The document ends abruptly with "SUMMARY," suggesting a potential incompleteness or a placeholder for further explanation.

    3. Technical Options (Detailed Options – Throughout)

    This is the core of the document and covers a lot of technical specifications. I'll categorize these by type:

    ️· Lamp Options (Implied): While not explicitly stated as "lamp options", references to wattage (26W, 32W, 42W, 57W, 70W, 85W, 120W) strongly suggest different lamp types are available.
    ️· Dual Switching (DS1 and DS2):
    - DS1: Allows individual external control of each lamp in a pair.
    - DS2: Allows external control of lamps in pairs, useful for fixtures with 4 or more lamps. For other lamp groupings, the factory should be consulted.
    - Wattage Combinations: Specific DS options are listed with wattage combinations (e.g., DS1-26, DS2-70, DS1-120).
    - Housing Considerations: DS2 options may require increased ballast housing length and stem size.
    ️· Quartz Lamp Emergency Socket (QS): A dedicated 120V power input for a quartz lamp in an emergency situation. Requires separate wiring and is not compatible with CFL lamps.
    ️· Pulse Start Ballast (PS): Requires a lens enclosure (check for compatibility) or a protected lamp version (contact factory). Add "PS" to the lamp wattage designation.
    ️· Quartz Lamp Emergency Socket (QS): 120V dedicated wiring is included.

    4. Important Notes

    ️· Design Changes: The note at the bottom states that Luminis can change design improvements or discontinue products without prior notice. This is a standard disclaimer in technical documentation.

    Overall Interpretation & Limitations:

    ️· Technical Audience: This is a document intended for lighting professionals, electrical engineers, or those with a good understanding of lighting terminology.
    ️· Specific Product: It appears to be specific to a particular line or model of Luminis fixtures. Without the product name, it's difficult to know exactly which fixtures these options apply to.
    ️· Outdated Information: The 2006/2007 revision date means some options might be discontinued or updated. Always verify availability with Luminis directly.
    ️· Missing Context: The abrupt end with "SUMMARY" suggests the document might be incomplete.

    Part No.PR2226
    ManufacturerLUMINIS
    Size194 Kbytes
    Pages4 pages
    DescriptionCeiling mount
    War ALLDATASHEET hilfreich?  [ DONATE ] 

    Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com