114 / 184 page ![]() 114 AT89C5130A/31A-M 4337C–USB–02/05 Table 87. Miscellaneous Status C0h Data byte in SSDAT has been transmitted; NOT ACK has been received No SSDAT action or No SSDAT action or No SSDAT action or No SSDAT action 0 0 1 1 0 0 0 0 0 0 0 0 0 1 0 1 Switched to the not addressed slave mode; no recognition of own SLA or GCA Switched to the not addressed slave mode; own SLA will be recognised; GCA will be recognised if GC=logic 1 Switched to the not addressed slave mode; no recognition of own SLA or GCA. A START condition will be transmitted when the bus becomes free Switched to the not addressed slave mode; own SLA will be recognised; GCA will be recognised if GC=logic 1. A START condition will be transmitted when the bus becomes free C8h Last data byte in SSDAT has been transmitted (AA=0); ACK has been received No SSDAT action or No SSDAT action or No SSDAT action or No SSDAT action 0 0 1 1 0 0 0 0 0 0 0 0 0 1 0 1 Switched to the not addressed slave mode; no recognition of own SLA or GCA Switched to the not addressed slave mode; own SLA will be recognised; GCA will be recognised if GC=logic 1 Switched to the not addressed slave mode; no recognition of own SLA or GCA. A START condition will be transmitted when the bus becomes free Switched to the not addressed slave mode; own SLA will be recognised; GCA will be recognised if GC=logic 1. A START condition will be transmitted when the bus becomes free Table 86. Status in Slave Transmitter Mode (Continued) Status Code (SSCS) Status of the 2-wire bus and 2-wire hardware Application Software Response Next Action Taken By 2-wire Software To/from SSDAT To SSCON STA STO SI AA Status Code (SSCS) Status of the 2-wire bus and 2-wire hardware Application Software Response Next Action Taken By 2-wire Software To/from SSDAT To SSCON STA STO SI AA F8h No relevant state information available; SI= 0 No SSDAT action No SSCON action Wait or proceed current transfer 00h Bus error due to an illegal START or STOP condition No SSDAT action 01 0 X Only the internal hardware is affected, no STOP condition is sent on the bus. In all cases, the bus is released and STO is reset. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |