Datenblatt-Suchmaschine für elektronische Bauteile |
|
TL-100NJ Datenblatt(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
TL-100NJ Datenblatt(HTML) 2 Page - List of Unclassifed Manufacturers |
2 / 4 page ![]() Powerful interrupting Capacities Limitation of System Damage Unique Contact Structure Selectivity Enhanced Switchgear The majority of distribution systems are designed to an ultimate short circuit rating (Icu). An Icu rated MCCB provides the optimum protection in terms of safe and economical selection. Certain applications may require protection which is designed to the more onerous service short circuit rating (Ics). Terasaki's TemBreak Plus range can provide a wide choice of MCCBs with superior Ics ratings up to 85kA at 440V AC. Terasaki's TemBreak Plus MCCBs achieve this exceptional current limiting performance by utilising a unique contact structure which we call the Fast Break Mechanism (FBM). The U-Shaped contact of this mechanism assists in the electromagnetic repulsion of the contact tips for fast arc extinction. The 50kA PowerBreaker Series uses one FBM per pole whilst the LimitorBreaker Series uses two FBM per pole to achieve its rating of 85kA. The need for a continuous and reliable power supply places increased emphasis on selectivity requirements in today's electrical distribution system. The Selectivity Series utilises microprocessor based protection, giving enhanced selectivity. This ensures a 3:1 ratio between the upstream and downstream MCCBs. For further details please refer to the selectivity table on page four of this leaflet. kA Conventional MCCB TemBreak Plus 50 9 I peak 2 4 6 8 10 I2 I1 0.1 0.2 0.3 0.4 IG 5 10 15 20 30 T1 0.1 0.15 0.2 0.25 0.3 SEC T2 0.1 0.2 0.3 0.4 0.8 SEC TG LONG TIME SHORT TIME INSTANTANEOUS GROUND FAULT TIME SETTING PICK UP SHORT TIME I2t OFF ON TEST IN SEC at 6 x I1 RATED CUR. (A) T I IG I1 T1 I2 T2 I3 TG BASE CUR. A IC x In 0.63 0.8 1.0 0.8 0.85 0.9 0.95 1.0 CURR. SETTING xI0 x I0 X In T2 SEC at 10 x I0 1250 1250 3 6 9 12 x I0 I3 CT RATED CURRENT In A During a fault condition, a circuit breaker with excellent current limiting ability such as TemBreak Plus, can substantially reduce damage to the electrical system and thus minimise downtime. This current limiting feature reduces the peak let through current (Ipeak) and energy let through (I t) during fault conditions. 2 Icu = 50kA Ics = 25kA XH125NJ Icu = 50kA Ics = 50kA XH125PJ Ics = 85kA Icu = 85kA TL100NJ Plus Plus t Innovators In Protection Technology I t 2 I t 2 Icu=o-co 2 Full Short Circuits Ics=o-co-co 3 Full Short Circuits |
Ähnliche Teilenummer - TL-100NJ |
|
Ähnliche Beschreibung - TL-100NJ |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |