| Datenblatt-Suchmaschine für elektronische Bauteile |
|
ADE7566 Datenblatt(PDF) 117 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7566 Datenblatt(HTML) 117 Page - Analog Devices |
|
117 / 136 page ![]() Preliminary Technical Data ADE7566/ADE7569 Rev. PrA | Page 117 of 136 Timer 2 is selected as the baud rate generator by setting TCLK and/or RCLK in Timer/Counter 2 Control SFR (T2CON, 0xC8). The baud rates for transmit and receive can be simultaneously different. Setting RCLK and/or TCLK puts Timer 2 into its baud rate generator mode as shown in Figure 92. In this case, the baud rate is given by the following formula: Mode 1 and Mode 3 Baud Rate = () [] () L RCAP H RCAP f CORE 2 : 2 65536 16 − × UART Timer Generated Baud Rates The high integer dividers in a UART block mean that high speed baud rates are not always possible. In addition, generating baud rates requires the exclusive use of a timer, rendering it unusable for other applications when the UART is required. To address this problem, each ADE7566/ADE7569 has a dedicated baud rate timer (UART timer) specifically for generating highly accurate baud rates. The UART timer can be used instead of Timer 1 or Timer 2 for generating very accurate high speed UART baud rates, including 115,200 bps. This timer also allows a much wider range of baud rates to be obtained. In fact, every desired bit rate from 12 bps to 393,216 bps can be generated to within an error of ±0.8%. The UART timer also frees up the other three timers, allowing them to be used for different applications. A block diagram of the UART timer is shown in Figure 91. ÷(1 + SBAUDF/64) UART TIMER Rx/Tx CLOCK fCORE UARTBAUDEN Rx CLOCK Tx CLOCK TIMER 1/TIMER 2 Rx CLOCK FRACTIONAL DIVIDER 0 0 1 1 TIMER 1/TIMER 2 Tx CLOCK ÷32 ÷2DIV + SBTH Figure 91. UART Timer, UART Baud Rate Two SFRs, Enhanced Serial Baud Rate Control SFR (SBAUDT, 0x9E) and UART Timer Fractional Divider SFR (SBAUDF, 0x9D), are used to control the UART timer. SBAUDT is the baud rate control SFR; it sets up the integer divider (DIV) and the extended divider (SBTH) for the UART timer. The appropriate value to write to the DIV[2:0] and SBTH[1:0] bits can be calculated using the following formula where fCORE is defined in the POWCON SFR (see Table 23). Note that the DIV value must be rounded down to the nearest integer. () 2 log 16 log ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ × = + Rate Baud f SBTH DIV CORE fCORE T2 PIN TR2 CONTROL TL2 (8 BITS) TH2 (8 BITS) RELOAD EXEN2 CONTROL T2EX PIN TRANSITION DETECTOR EXF 2 TIMER 2 INTERRUPT RCAP2L RCAP2H TIMER 2 OVERFLOW 2 16 16 RCLK TCLK Rx CLOCK Tx CLOCK 0 0 1 1 1 0 SMOD TIMER 1 OVERFLOW C/ T2 = 0 C/ T2 = 1 NOTE: AVAILABILITY OF ADDITIONAL EXTERNAL INTERRUPT Figure 92. Timer 2, UART Baud Rates |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |