The **8502SHO2V02S** is a specific model of a NEMA-rated magnetic contactor manufactured by Square D (Schneider Electric). It is part of the Type S family, designed for controlling AC motors and power circuits.
---
### ## Technical Specifications Breakdown
The part number encodes specific electrical and physical characteristics. Here is the breakdown of the electronic components and ratings:
| Feature | Specification | Description |
| :--- | :--- | :--- |
| **Type** | 8502 | Non-reversing AC Magnetic Contactor |
| **NEMA Size** | Size 0 | Rated for up to 18 Amps (Continuous) |
| **Pole Configuration** | 3-Pole | Designed for 3-phase electrical systems |
| **Enclosure Type** | Open (S) | No protective outer box; intended for panel mounting |
| **Coil Voltage** | 110V/120V AC (V02) | 120VAC @ 60Hz or 110VAC @ 50Hz |
| **Phase** | 3-Phase | Standard industrial motor control |
| **Switching Type** | SHO | Separate control circuit (No fused control transformer) |
---
### ### Key Electronic Components
#### 1. The Magnetic Coil (V02)
The heart of the contactor is the electromagnetic coil. When 120V AC is applied to terminals A1 and A2, it creates a magnetic field that pulls the armature down, closing the high-power contacts.
* **Inrush VA:** The power required to initially close the contacts.
* **Sealed VA:** The lower power required to keep the contacts closed.
#### 2. Power Contacts
The device features three heavy-duty silver-cadmium oxide contacts. These are designed to resist "welding" and arcing when switching inductive motor loads.
* **Max Voltage:** 600V AC.
* **Horsepower Ratings:**
* 3 HP @ 200/230V AC.
* 5 HP @ 460/575V AC.
#### 3. Auxiliary Contacts
The "S" suffix often indicates the inclusion of or compatibility with specific auxiliary contact blocks. These are low-power switches used for logic feedback (e.g., telling a PLC that the motor is running) or for interlocking circuits.
---
### ### Physical Installation & Application
* **Mounting:** Designed for 35mm DIN rail or direct screw mounting onto a backplane.
* **Wiring:** Uses pressure wire connectors (lugs) suitable for copper wire.
* **Typical Use:** Used in HVAC systems, pump control, and industrial conveyor belts where rugged, NEMA-rated reliability is required over standard IEC contactors.
---
- ⤷
What is the difference between this NEMA-rated contactor and an IEC-rated contactor?
- ⤷ Can I add an overload relay to this specific model to protect a motor?
- ⤷ What is the procedure for replacing the 120V coil if it fails?