8536SCO2V03
AI

## Technical Overview: Square D 8536SCO2V03
The **8536SCO2V03** is a high-performance NEMA-rated magnetic starter manufactured by Schneider Electric under the Square D brand. It is primarily used to start and stop induction motors and provide thermal overload protection.
---
### 1. Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Product Type** | NEMA Magnetic Starter |
| **NEMA Size** | Size 1 |
| **Poles** | 3-Pole (3-Phase) |
| **Continuous Current Rating** | 27 Amperes |
| **Control Voltage** | 240V AC @ 60Hz / 220V AC @ 50Hz |
| **Motor Power (HP)** | 7.5 HP @ 230V / 10 HP @ 460/575V |
| **Enclosure Type** | Open (No enclosure provided) |
| **Overload Type** | Melting Alloy (Thermal) |
---
### 2. Major Electronic & Electromechanical Components
The device consists of three main sub-assemblies that work together to control the motor circuit:
#### A. The Contactor (Power Switching)
The core of the unit is a **NEMA Size 1 Contactor**. It uses a set of high-conductivity silver-cadmium oxide contacts. When the control coil is energized, the electromagnetic force pulls the armature down, closing the three power poles to complete the circuit to the motor.
#### B. The Magnetic Coil (V03 Suffix)
The **V03** designation specifically identifies the voltage rating of the electromagnetic coil.
* **Voltage:** 220V/240V AC.
* **Function:** It converts electrical energy into a magnetic field to physically move the contact carrier.
* **Terminals:** Usually labeled A1 and A2.
#### C. The Overload Relay (Protection)
This starter uses a **Melting Alloy Overload Relay**.
* **Sensing:** It uses thermal units (heaters) to monitor the current flowing to the motor.
* **Protection Logic:** If the motor draws excessive current, the heaters melt a specific solder alloy, releasing a spring-loaded mechanism that opens the control circuit and shuts down the contactor.
* **Note:** Thermal units (heaters) are usually sold separately based on the specific Full Load Amps (FLA) of your motor.
---
### 3. Wiring Configuration Example
The following represents a typical 3-phase wiring logic:
```text
L1, L2, L3 ----> [ Contactor Poles ] ----> [ Overload Heaters ] ----> Motor T1, T2, T3
^
|
[ 240V Control Source (A1/A2) ]
```
---
### 4. Key Maintenance Parts
If you are repairing or maintaining this unit, these are the common replaceable parts:
* **Replacement Coil:** Class 9998 Type SB (Verify voltage).
* **Contact Kit:** Class 9998 Type SL2 (Includes all 3 poles).
* **Thermal Units:** Type B (Selection depends on motor nameplate FLA).
---
- ⤷
What are the specific heater (thermal unit) part numbers for a 5HP motor using this starter?
- ⤷ Can this starter be converted to run on 120V control power?
- ⤷ What is the difference between this NEMA starter and an IEC-rated starter?