8536SHO2V06
AI

The **8536SHO2V06** is a specific model of a NEMA-rated magnetic motor starter manufactured by **Schneider Electric (Square D)**. It is part of the Type S series, designed for the induction of AC motors across various industrial applications.
---
## 1. Technical Specifications
Below are the primary electronic and physical specifications for the 8536SHO2V06:
| Feature | Specification |
| :--- | :--- |
| **Manufacturer** | Schneider Electric (Square D) |
| **Product Type** | Magnetic Motor Starter |
| **NEMA Size** | Size 6 |
| **Pole Configuration** | 3-Pole (3P) |
| **Voltage Rating** | 600V AC (Maximum) |
| **Continuous Current** | 540 Amperes |
| **Coil Voltage** | 440V AC @ 50Hz / 480V AC @ 60Hz |
| **Overload Type** | Melting Alloy (standard) |
| **Enclosure Type** | Open (No NEMA 1/3R/4/12 box included) |
---
## 2. Key Electronic Components
The 8536SHO2V06 functions through the coordination of three main sub-assemblies:
### A. The Electromagnetic Coil (V06)
The suffix **V06** specifically denotes the control voltage of the internal solenoid coil.
- **Input:** 480V AC (60Hz) or 440V AC (50Hz).
- **Function:** When energized, it creates a magnetic field that pulls the main contacts closed, allowing high-current power to flow to the motor.
### B. Power Contacts
The starter utilizes heavy-duty copper alloy contacts designed to handle the **540A** continuous current rating of a NEMA Size 6 frame.
- These contacts are replaceable and are engineered to minimize arcing during high-load switching.
### C. Overload Protection
While the basic unit is designed for **Melting Alloy** thermal units, modern variations can be fitted with Solid-State Overload Relays (SSOLRs).
- **Thermal Units:** These must be sized separately based on the Motor Full Load Amps (FLA).
- **Function:** They detect excessive current draw (heat) and mechanically trip the starter to prevent the motor windings from burning out.
---
## 3. Horsepower (HP) Ratings
The electronic capacity of this starter varies based on the operational voltage of the motor being driven:
| Voltage | Max Horsepower (HP) |
| :--- | :--- |
| **200V AC** | 150 HP |
| **230V AC** | 200 HP |
| **460V AC** | 400 HP |
| **575V AC** | 400 HP |
---
## 4. Wiring and Terminal Connections
The starter utilizes large-scale terminal lugs to accommodate the heavy-gauge cabling required for 540A service.
- **L1, L2, L3:** Line side power input.
- **T1, T2, T3:** Load side output to the motor.
- **Holding Circuit:** Typically includes an auxiliary contact (normally open) to allow for momentary push-button control (Start/Stop).
- ⤷
What are the compatible thermal unit part numbers for this starter?
- ⤷ Can the V06 coil be swapped for a 120V or 240V coil?
- ⤷ What is the physical footprint and mounting dimension for a NEMA Size 6 starter?