8736SDO2V06H30
AI

The **8736SDO2V06H30** is a specific model of a **Reversing Magnetic Starter** from the Square D (Schneider Electric) Type S line. These devices are used to start, stop, and reverse the direction of three-phase AC motors while providing overload protection.
Below is a breakdown of its electronic and electromechanical parts:
### 1. General Specifications
| Feature | Detail |
| :--- | :--- |
| **Manufacturer** | Square D (Schneider Electric) |
| **Type** | S (NEMA Rated) |
| **NEMA Size** | 2 (45 Amperes) |
| **Configuration** | Reversing |
| **Enclosure Type** | Open (No outer box included) |
| **Phase** | 3-Phase |
---
### 2. Key Internal Components
#### A. Contactor Assembly (The Switching Mechanism)
This unit consists of two interconnected contactors—one for "Forward" and one for "Reverse."
* **Contacts:** High-conductivity silver alloy points designed to handle high inrush currents.
* **Mechanical Interlock:** A physical safety mechanism that prevents both the forward and reverse contactors from closing at the same time, which would cause a phase-to-phase short circuit.
#### B. The Coil (V06 Code)
The "V06" in the part number identifies the control voltage for the electromagnetic coil.
* **Voltage:** 480V AC @ 60Hz / 440V AC @ 50Hz.
* **Function:** When energized, the coil creates a magnetic field that pulls the power contacts closed to start the motor.
#### C. Motor Logic Solid-State Overload Relay (H30 Code)
The "H30" suffix indicates that this starter is equipped with a **Motor Logic** solid-state overload relay.
* **Electronic Sensing:** Unlike traditional thermal heaters (bimetallic), this uses internal sensors to monitor current flow.
* **Trip Class:** Usually selectable (Class 10/20), protecting the motor from overheating or phase loss.
* **Adjustability:** Features a dial to set the Full Load Amps (FLA) to match the specific motor nameplate.
---
### 3. Part Number Nomenclature Breakdown
| Code | Meaning |
| :--- | :--- |
| **8736** | Reversing Starter (NEMA Type) |
| **S** | Series / Frame Style |
| **D** | NEMA Size 2 (Handles up to 25 HP @ 480V) |
| **O** | Open Style Enclosure (for mounting inside another panel) |
| **2** | 3-Pole Power Configuration |
| **V06** | 480V 60Hz / 440V 50Hz Control Voltage |
| **H30** | Solid-State Overload Relay (Motor Logic) |
---
### 4. Application Logic
This device is typically used in industrial environments for:
* **Conveyor Belts:** To move items forward and backward.
* **Hoists/Cranes:** To lift and lower loads.
* **Large Valves:** To open and close motorized actuators.
- ⤷