ADS-BB-R
AI

The **ADS-BB-R** is a specific electronic component typically used as a **Remote Battery Box** or power supply module, often associated with proximity sensors, automatic door systems, or specific industrial controller setups (commonly found in the Optex or BEA catalogs for door automation).
Below is a breakdown of the electronic parts, specifications, and functions of the ADS-BB-R.
---
### 1. Technical Specifications
The ADS-BB-R serves as the "brain" or interface for sensor beams. It manages the power distribution and signal processing between the infrared heads and the main controller.
| Feature | Specification |
| :--- | :--- |
| **Input Voltage** | 12 to 24V AC or DC |
| **Current Consumption** | 160mA Max. |
| **Output Contacts** | Form C Relay (N.O. / N.C.) |
| **Relay Contact Rating** | 1A at 30V DC |
| **Detection Channels** | Supports up to 2 pairs of sensor heads |
| **Operating Temperature** | -20°C to +55°C (-4°F to 131°F) |
---
### 2. Key Internal Components
The unit is composed of several critical electronic sub-assemblies:
#### A. Microprocessor / Logic Controller
The central integrated circuit (IC) processes the signals received from the infrared receiver heads. It determines if the beam is broken and manages the "Hold Time" logic.
#### B. Form C Relay
This is the physical mechanical switch that toggles the output state.
* **Common (COM)**
* **Normally Open (NO)**
* **Normally Closed (NC)**
#### C. Potentiometers (Adjustment Dials)
The board usually contains small variable resistors used to adjust:
* **Sensitivity:** Increases or decreases the threshold for beam interruption.
* **Self-Diagnosis:** Some versions include a test cycle potentiometer.
#### D. Connection Terminals
Screw-down or plug-in terminal blocks provide the interface for:
1. **Power Input:** Terminals 1 & 2.
2. **Relay Output:** Terminals 3, 4, & 5.
3. **Sensor Input:** Specific ports for the Emitter (TX) and Receiver (RX) cables.
---
### 3. Wiring Configuration
The following table outlines the standard wiring logic for the ADS-BB-R controller:
| Terminal Number | Function | Description |
| :--- | :--- | :--- |
| 1 & 2 | Power Input | Connects to 12-24V source |
| 3 | Common (COM) | The shared relay contact |
| 4 | Normally Closed (NC) | Connected to COM when beam is clear |
| 5 | Normally Open (NO) | Connected to COM when beam is blocked |
---
### 4. Operational Indicators (LEDs)
The board features diagnostic LEDs to help technicians troubleshoot the circuit:
* **Green LED:** Indicates the power is ON and the system is in standby.
* **Red LED:** Indicates a detection event (the beam is broken and the relay has triggered).
---
- ⤷
How do you wire the sensor heads to the ADS-BB-R unit?
- ⤷ What are the common causes for the Red LED to stay on constantly?
- ⤷ Can the ADS-BB-R be used with 3rd party infrared sensors?