BGL36070LU
AI

### BGL36070LU: Technical Overview
The **BGL36070LU** is a high-performance, molded case circuit breaker (MCCB) belonging to the **PowerPact B-Frame** family manufactured by Schneider Electric (Square D). It is designed to provide overcurrent protection and switching for electrical distribution systems.
---
### Core Specifications
The following table outlines the primary electrical and physical characteristics of the BGL36070LU:
| Feature | Specification |
| :--- | :--- |
| **Frame Type** | PowerPact B-Frame |
| **Number of Poles** | 3-Pole (3P) |
| **Current Rating ($I_n$)** | 70 Amperes |
| **Voltage Rating ($U_e$)** | 600Y/347 VAC |
| **Interrupting Rating** | 35 kA @ 480V / 65 kA @ 240V |
| **Trip Unit Type** | Thermal-Magnetic (Non-adjustable) |
| **Connection Type** | EverLink Lugs (Line side) / EverLink Lugs (Load side) |
| **Mounting Mode** | Unit Mount (Bolt-on) |
| **Control Logic** | Micrologic (Standard Toggle) |
---
### Electronic and Internal Components
While this specific model uses a **Thermal-Magnetic** trip unit rather than a fully digital/electronic trip unit, it incorporates several sophisticated engineering components:
#### 1. Thermal-Magnetic Trip Unit
* **Thermal Protection:** Uses a bimetallic strip that bends in response to heat buildup. This provides a "time-delay" trip for sustained overloads.
* **Magnetic Protection:** Uses an electromagnetic solenoid that reacts instantaneously to high-level short circuits to prevent equipment damage.
#### 2. EverLink™ Connector Technology
The "LU" designation refers to the integrated **EverLink lugs**. This is a patented terminal technology that includes a spring-loaded mechanism to compensate for "creep" (the tendency of conductors to loosen over time). This ensures a permanent, high-pressure electrical connection without the need for periodic retightening.
#### 3. Integrated Control and Signaling
The B-Frame architecture supports various field-installable electronic accessories:
* **Auxiliary Switches (OF):** Indicate whether the breaker is open or closed.
* **Error Switches (SD):** Indicate if the breaker has tripped due to a fault.
* **Voltage Releases:** Including Shunt Trips (MX) for remote tripping or Undervoltage Releases (MN).
---
### Dimensions and Compliance
* **Height:** 5.39 in (137 mm)
* **Width:** 3.19 in (81 mm)
* **Depth:** 3.15 in (80 mm)
* **Certifications:** UL Listed, CSA Certified, IEC Rated, and CE Marked.
- ⤷
What is the difference between EverLink lugs and standard mechanical lugs?
- ⤷ Can this breaker be used in a reverse-feed application?
- ⤷ What are the compatible shunt trip accessory part numbers for the B-Frame?