DL30-G-R
AI

The **DL30-G-R** is a high-performance, web-enabled remote terminal unit (RTU) and data logger manufactured by **M-System**. It is primarily used in industrial automation for remote monitoring, data acquisition, and IoT gateway applications.
---
## 1. Core Electronic Components & Architecture
The device is built on an industrial-grade embedded architecture designed for 24/7 reliability.
| Component Category | Description |
| :--- | :--- |
| **CPU / Processor** | High-speed 32-bit embedded microprocessor for real-time OS (RTOS) handling and web serving. |
| **Memory** | Internal non-volatile memory for OS and logging; supports SD Card expansion for long-term data storage. |
| **Communication Chips** | Integrated Ethernet controllers (100BASE-TX) and serial interface drivers (RS-485). |
| **Power Supply Unit** | DC-powered (usually 24V DC) with internal filtering to handle industrial noise and ripples. |
---
## 2. Interface and Connectivity Features
The electronic design focuses on bridging local sensor data to wide-area networks (WAN).
### A. I/O Expansion
The DL30-G-R acts as a "Base Module." It connects to various **R30 series I/O modules** via a backplane bus.
* **Analog Input:** 0-10V, 4-20mA.
* **Discrete Input:** Dry contacts or 24V DC signals.
* **Relay Outputs:** For remote control of machinery.
### B. Network Protocols
The internal firmware supports standard industrial protocols:
* **Modbus/TCP:** To communicate with PLCs and HMIs.
* **HTTP/HTTPS:** For the built-in web server used for configuration and data viewing.
* **FTP/SFTP:** For uploading logged data files to a remote server.
* **SMTP:** For sending email alerts based on alarm triggers.
---
## 3. Physical & Electrical Specifications
| Specification | Details |
| :--- | :--- |
| **Supply Voltage** | 24V DC (Operating range: 24V ±10%) |
| **Current Consumption** | Approx. 130 mA (Base unit only) |
| **Isolation** | 1500V AC between network, I/O, and power. |
| **Mounting** | DIN rail mounting (35mm). |
| **Local Port** | Mini-B USB port for local PC configuration. |
---
## 4. Operational Logic
1. **Data Collection:** The unit polls data from attached I/O modules or Modbus slaves.
2. **Processing:** It applies scaling, alarm limits, and timestamping.
3. **Storage:** Data is written to the internal memory or SD card in CSV format.
4. **Reporting:** The electronic logic triggers a data upload via FTP or sends an email if a threshold is breached.
- ⤷
How do you configure the I/O mapping for the DL30-G-R?
- ⤷ What is the maximum SD card capacity supported by this unit?
- ⤷ Can the DL30-G-R function as a Modbus Master and Slave simultaneously?