Datenblatt-Suchmaschine für elektronische Bauteile
  German  ▼
ALLDATASHEETDE.COM

X  

  • FAP-51-R

  • AI
    The **FAP-51-R** is a specialized electronic component primarily used as a **Flame Sensor (UV Sensor)** in industrial burner systems, specifically designed for use with Furukawa or similar boiler/combustion control systems. Below is a detailed breakdown of its electronic characteristics and specifications. --- ### 1. Technical Specifications The FAP-51-R operates on the principle of ultraviolet (UV) radiation detection. It is designed to sense the presence of a flame by reacting to the UV light emitted during combustion. | Feature | Specification | | :--- | :--- | | **Sensor Type** | Ultraviolet (UV) Flame Detector | | **Spectral Response** | 185 nm to 260 nm (UV-C range) | | **Operating Voltage** | AC 100V / 200V (depending on the control unit) | | **Ambient Temperature** | -20°C to +60°C | | **Connection Type** | Lead wires or specialized plug-in base | | **Compatibility** | Used with Burner Controllers (e.g., FR series) | --- ### 2. Core Electronic Components The device is composed of several critical electronic segments: * **UV Tube (Glow Discharge Tube):** The heart of the sensor. It contains an inert gas that ionizes when hit by UV photons within a specific wavelength. This ionization creates a measurable electrical pulse. * **Filtering Lens:** A specialized glass or quartz window that allows only UV light to pass through while blocking visible light and infrared (to prevent false triggers from hot furnace walls). * **Encapsulation:** A ruggedized housing designed to protect the sensitive internal electronics from high heat and vibration. --- ### 3. Working Principle The electronic operation follows a specific sequence: 1. **Detection:** When the burner is lit, the UV radiation hits the cathode inside the sensor tube. 2. **Ionization:** Electrons are emitted, causing the gas inside to become conductive. 3. **Signal Output:** This conductivity allows a current to flow to the **Flame Relay** or **Burner Management System (BMS)**. 4. **Safety Logic:** If the flame goes out, the UV source disappears, the gas stops conducting, and the electronic circuit opens, triggering an immediate fuel shut-off for safety. --- ### 4. Maintenance and Troubleshooting Because the FAP-51-R is an electronic sensor, it is subject to degradation over time. * **Sensitivity Loss:** The UV tube inside has a finite lifespan (usually measured in thousands of hours). As the gas depletes, the sensor becomes "blind." * **Soot Accumulation:** Even if the electronics are functional, physical buildup on the lens will block UV rays, leading to false "Flame Failure" alarms. * **Wiring Integrity:** Ensure the shielded cables are intact to prevent electromagnetic interference (EMI) from the ignition transformer. ---
    ✨ Follow-up Questions
    • ⤷ What are the compatible burner controller models for the FAP-51-R?
    • ⤷ How do you test the voltage output of a FAP-51-R sensor?
    • ⤷ What is the typical lifespan of the internal UV tube in this model?