FLM-D1-R
AI

The **FLM-D1-R** is an electronic component primarily used in fire alarm systems. Specifically, it is a **Dual Relay Module** within the Bosch family of fire safety devices. It is designed to provide dry contact relay outputs that are controlled by a Fire Alarm Control Panel (FACP) via the Local Security Network (LSN).
---
### 1. Key Technical Specifications
The following table summarizes the primary electrical and physical characteristics of the FLM-D1-R:
| Specification | Details |
| :--- | :--- |
| **Product Type** | Dual Relay Module (Addressable) |
| **Input Voltage** | 15 V DC to 33 V DC (LSN range) |
| **Relay Contact Type** | 2 × Form C (Changeover contacts) |
| **Contact Rating (Resistive)** | 2 A @ 30 V DC / 0.5 A @ 125 V AC |
| **Current Consumption** | Approx. 1.7 mA (Normal operation) |
| **Addressing** | Manual (Rotary switches) or Automatic |
| **Operating Temperature** | -20 °C to +50 °C |
---
### 2. Core Electronic Components & Functions
The module operates as an interface between the low-power digital signal loop and high-power auxiliary devices.
* **LSN Bus Interface:** The module contains integrated circuitry to communicate with the Bosch LSN bus. It receives digital commands to toggle the relays and sends status reports back to the panel.
* **Form C Relays:** These are the "mechanical" electronic parts. A Form C relay includes a Common (C), Normally Open (NO), and Normally Closed (NC) contact. This allows the device to either complete or break a circuit when activated.
* **Rotary Switches:** Located on the PCB, these hardware switches allow technicians to manually set the module's address (0-254) for identification by the control panel.
* **On-board LEDs:** Typically features a status LED (often red or green) that indicates the communication status with the LSN loop or activation state of the relays.
---
### 3. Application Use Cases
Because it provides two independent dry contacts, the FLM-D1-R is commonly used to trigger:
1. **Elevator Recall:** Sending a signal to the elevator controller to return to the ground floor during a fire.
2. **HVAC Shutdown:** Turning off air handling units to prevent the spread of smoke.
3. **Door Release:** De-energizing magnetic door holders to close fire doors.
4. **Extinguishing Systems:** Triggering secondary fire suppression or signaling external sirens.
---
### 4. Wiring Diagram Concept
While specific wiring depends on the load, the general terminal structure is as follows:
```text
[ LSN In + / - ] ----> [ Internal Microprocessor ] ----> [ Relay 1 (C/NO/NC) ]
[ LSN Out + / - ] ----> [ Relay 2 (C/NO/NC) ]
```
---
- ⤷
How do you set the address on the FLM-D1-R using the rotary switches?
- ⤷ What is the difference between a Form C relay and a standard NO relay in this module?
- ⤷ Can the FLM-D1-R be used with non-Bosch fire alarm panels?