The **FLM-H4-R** is an electronic component primarily associated with **Bosch Security Systems**. It is a **Field Longitudinal Module** designed for fire alarm systems, specifically serving as a **4-wire Conventional Zone Monitor**.
Below is a detailed breakdown of its electronic specifications and functions.
---
### 1. Technical Specifications
The following table highlights the core electrical characteristics of the FLM-H4-R module:
| Parameter | Value / Specification |
| :--- | :--- |
| **Operating Voltage** | 24 VDC (Nominal) |
| **Current Consumption** | < 100 mA |
| **Input Channels** | 1 (Monitoring 4-wire conventional detectors) |
| **Output Type** | Relay Contact (Fail-safe operation) |
| **EOL Resistance** | 3.9 kΩ (Standard) |
| **Protection Class** | IP 30 |
| **Operating Temperature** | -20 °C to +50 °C |
---
### 2. Key Electronic Functions
The FLM-H4-R acts as an interface between a fire panel's digital bus and conventional sensing devices.
* **Zone Monitoring:** It monitors a single branch of 4-wire conventional detectors for alarms, short circuits, and wire breaks (open circuits).
* **Reset Functionality:** It features an integrated electronic power-reset mechanism. This allows the fire panel to briefly interrupt power to the 4-wire detectors to reset them after a triggered alarm.
* **Galvanic Isolation:** The module provides electrical isolation between the Local SecurityNetwork (LSN) bus and the conventional zone, protecting the main panel from surges or faults on the field wiring.
* **Addressing:** It uses rotary switches or electronic software addressing to identify itself on the LSN loop.
---
### 3. Wiring Configuration
The "H4" in the model name signifies its specialization for **4-wire** circuits. In this setup:
1. **Two wires** are used for the 24V power supply to the detectors.
2. **Two wires** are used for the alarm signaling loop.
#### Typical Connection Diagram (Simplified)
```text
[ FIRE PANEL LSN BUS ] <---> [ FLM-H4-R MODULE ]
|
+--- [ 24V Power Out ] ---> [ Detector 1 ] ... [ Detector N ]
|
+--- [ Alarm Input ] <--- [ EOL Resistor ]
```
---
### 4. Application Use Case
This module is typically used when upgrading an older building that already has 4-wire smoke detectors installed, or when using specialized detectors (like beam detectors or flame detectors) that require separate 24V power and a relay contact interface to talk to a modern addressable fire panel.
- ⤷
What is the difference between the FLM-H4-R and the 2-wire FLM-420-S2 module?
- ⤷ How do you set the LSN address on this module?
- ⤷ What specific EOL resistor values are compatible for fault detection?