FTS-5E-R
AI

The **FTS-5E-R** is an industrial-grade **Spring-Loaded Temperature Sensor** (Thermocouple or RTD), typically utilized in plastic extrusion, injection molding, and packaging machinery.
Below is a breakdown of its electronic components and technical specifications.
---
## 1. Core Electronic Components
The FTS-5E-R functions primarily as a transducer, converting thermal energy into an electrical signal.
| Component | Description | Function |
| :--- | :--- | :--- |
| **Sensing Element** | Typically a **Type J** or **Type K** thermocouple, or a **Pt100** RTD. | Generates a millivolt signal (TC) or changes resistance (RTD) based on temperature. |
| **Spring Mechanism** | A stainless steel compression spring. | Ensures the tip maintains constant physical contact with the surface for accurate heat transfer. |
| **Lead Wires** | Fiberglass or Teflon-insulated wires, often with a stainless steel overbraid. | Transmits the electrical signal to the controller or PLC. |
| **Bayonet Cap** | A slotted metal cap (usually 12mm or 14mm). | Secures the sensor into a bayonet adapter via a twist-lock mechanism. |
---
## 2. Technical Specifications
Depending on the specific configuration of the "5E" series, the electrical characteristics usually fall within these ranges:
### Electrical & Thermal Data
* **Sensor Type:** Type J (Iron/Constantan) is most common for this form factor.
* **Temperature Range:**
* **Type J:** 0°C to 450°C (32°F to 842°F).
* **Type K:** 0°C to 600°C (32°F to 1112°F).
* **Accuracy:** Standard Limits of Error (±2.2°C or ±0.75%).
* **Insulation Resistance:** >100 MΩ at 500V DC (at room temperature).
---
## 3. Wiring Configuration
The wiring depends on whether the unit is a Thermocouple or an RTD.
### Thermocouple Wiring (Most Common)
| Wire Color (ANSI) | Polarity | Material |
| :--- | :--- | :--- |
| **White** | Positive (+) | Iron (Type J) |
| **Red** | Negative (-) | Constantan (Type J) |
### RTD Wiring (3-Wire)
* **Red (x2):** Common/Compensation loop.
* **White (x1):** Main signal line.
---
## 4. Key Features for Electronics Integration
1. **Cold Junction Compensation (CJC):** If using a thermocouple, the receiving electronic controller must have CJC to account for the temperature at the connection terminals.
2. **Shielding:** The stainless steel overbraid (the "R" often denotes a ruggedized or braided lead) acts as an EMI shield to prevent electrical noise from heaters or motors from interfering with the low-voltage signal.
3. **Response Time:** Because it is spring-loaded, the "Time Constant" is minimized due to the elimination of air gaps between the sensor and the well.
---
- ⤷
What are the differences between Type J and Type K versions of this sensor?
- ⤷ How do I test if an FTS-5E-R sensor is malfunctioning using a multimeter?
- ⤷ What is the purpose of the 'R' suffix in the part number?