IM1-231EX-R
AI

The **IM1-231EX-R** is a high-performance **Isolation Amplifier (Switching Amplifier)** manufactured by **Turck**. It is primarily designed for intrinsic safety applications, acting as an interface between sensors in hazardous areas (Ex-zones) and controllers in safe areas.
---
### 1. Key Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Manufacturer** | Turck |
| **Number of Channels** | 2-channel (Dual output) |
| **Input Type** | NAMUR sensors or dry contacts |
| **Output Type** | 2 x Relays (Changeover/SPDT) |
| **Supply Voltage** | 20…250 VAC / 20…125 VDC |
| **Isolation Voltage** | 2.5 kV |
| **Mounting** | DIN Rail (35mm) |
| **Protection Class** | IP20 |
---
### 2. Functional Components & Connectivity
The device acts as a galvanic isolator, ensuring that high-voltage surges or faults in the power supply do not reach the volatile hazardous environment.
#### A. Input Side (Hazardous Area)
* **NAMUR Compliance:** Designed to monitor sensors according to EN 60947-5-6.
* **Wire-Break Detection:** Can detect if the wire to the sensor is cut or if there is a short circuit (monitored via current levels).
#### B. Output Side (Safe Area)
* **Relay Logic:** Two independent relay outputs. These can be configured for "Light" or "Dark" switching (normally open or normally closed logic).
* **Switching Frequency:** Limited by the mechanical nature of the relays (typically ≤ 10 Hz).
#### C. Control Switches (Front Panel)
The device features DIP switches on the front to configure:
1. **Output Mode:** To select between signal inversion or non-inversion.
2. **Monitoring:** To enable or disable line fault monitoring (LFD).
---
### 3. Safety and Certifications
The "EX" in the part number signifies its role in explosive atmospheres.
* **ATEX/IECEx:** Approved for connection to sensors located in Zones 0, 1, 2, 20, 21, and 22.
* **SIL Rating:** Typically rated for **SIL2** applications according to IEC 61508, making it suitable for functional safety loops.
---
### 4. Circuit Diagram Block (Simplified)
```mermaid
graph LR
subgraph Hazardous_Area
S[NAMUR Sensor]
end
subgraph IM1-231EX-R
I[Input Stage] --> ISOL[Galvanic Isolation]
ISOL --> LOGIC[Logic/DIP Switches]
LOGIC --> R[Relay Output]
end
subgraph Safe_Area
PLC[PLC / Controller]
R --> PLC
end
```
- ⤷
What is the difference between the IM1-231EX-R and the IM1-22EX-R model?
- ⤷ How do you configure the DIP switches for wire-breakage monitoring?
- ⤷ What are the maximum voltage and current limits for the relay contacts?