M2RTS-R-DA-M2
AI

The **M2RTS-R-DA-M2** belongs to the M2-Series of signal conditioners/transmitters, typically manufactured by companies like **M-System**. This specific model is a **Potentiometer Transmitter**, designed to convert resistance changes from a potentiometer into a standard analog signal.
---
### 1. Model Breakdown
The alphanumeric code identifies the specific electronic configuration of the unit:
| Segment | Identification | Description |
| :--- | :--- | :--- |
| **M2RTS** | Model Series | Potentiometer Transmitter (Plug-in base) |
| **R** | Input Type | Potentiometer (Total resistance 100 $\Omega$ to 10 k$\Omega$) |
| **DA** | Output Type | 4 – 20 mA DC (Current Loop) |
| **M2** | Power Supply | 100 – 240 V AC (Universal AC supply) |
---
### 2. Key Electronic Specifications
The internal circuitry is designed for high precision and industrial-grade isolation.
* **Input Circuit:**
* **Excitation Voltage:** Approx. 0.5 V DC.
* **Allowable Resistance:** Total resistance must be within 100 $\Omega$ to 10 k$\Omega$.
* **Output Circuit:**
* **Load Resistance:** Maximum 750 $\Omega$.
* **Type:** Active 4-20mA current source.
* **Isolation Architecture:**
* **3-Port Isolation:** Input, Output, and Power are all galvanically isolated from each other.
* **Isolation Resistance:** $\ge$ 100 M$\Omega$ at 500 V DC.
* **Performance:**
* **Accuracy:** $\pm 0.1\%$ of span.
* **Response Time:** $\le$ 0.5 seconds (0 to 90%).
---
### 3. Electronic Components & Features
#### A. Signal Conditioning
The unit utilizes an internal operational amplifier circuit to provide **Zero and Span adjustments**. These are accessible via the front panel, allowing the user to calibrate the 0% and 100% resistance points to the 4mA and 20mA outputs respectively.
#### B. Burnout Protection
This model includes electronic **burnout protection**. If the potentiometer wire breaks (open circuit), the transmitter can be configured to drive the output signal to a specific state (Upscale $\ge$ 20.9 mA or Downscale $\le$ 3.5 mA) to signal a fault to the PLC/DCS.
#### C. Power Supply Section
The "M2" designation indicates a wide-range switching power supply capable of handling **100V to 240V AC**. It includes internal surge filtering to protect against electrical noise common in industrial environments.
---
### 4. Terminal Connection Map
| Terminal No. | Function | Description |
| :--- | :--- | :--- |
| **1** | Output (+) | 4-20mA Positive |
| **2** | Output (-) | 4-20mA Negative |
| **3** | Input (H) | Potentiometer High (CW) |
| **4** | Input (S) | Potentiometer Wiper (S) |
| **5** | Input (L) | Potentiometer Low (CCW) |
| **7** | Power (U) | AC Line Input |
| **8** | Power (V) | AC Neutral Input |
---
- ⤷