MAH76FAG-R
AI

The **MAH76FAG-R** is a specific technical component part number, most commonly associated with **DC Axial Fans** (typically manufactured by brands like Delta Electronics or similar industrial cooling suppliers). These fans are designed for high-performance thermal management in servers, telecommunications, and industrial equipment.
Below is a breakdown of the electronic and mechanical specifications for this component.
---
### 1. Technical Specifications
| Feature | Specification (Typical) |
| :--- | :--- |
| **Component Type** | DC Axial Fan |
| **Voltage (Rated)** | 12V DC (Standard range 7V - 13.8V) |
| **Bearing Type** | Dual Ball Bearing (Long life, high reliability) |
| **Frame Material** | Plastic (UL 94V-0 Rated) |
| **Impeller Material** | Plastic (UL 94V-0 Rated) |
| **Termination** | 4-Wire Lead (PWM + Tachometer Output) |
| **Signal Type** | Frequency Generator (FG) or Pulse Width Modulation (PWM) |
---
### 2. Pinout Configuration (4-Wire)
The "R" suffix often denotes a specific wiring configuration or a signal type (like a rotation detector). Most 4-wire fans follow this standard logic:
| Wire Color | Function | Description |
| :--- | :--- | :--- |
| **Black** | GND | Ground / Negative terminal |
| **Red** | VCC | +12V Power Supply |
| **Yellow** | Tachometer | Speed sensor signal (2 pulses per revolution) |
| **Blue** | PWM | Input signal to control fan speed dynamically |
---
### 3. Key Electronic Features
* **PWM Speed Control:** Allows the system motherboard or controller to adjust the fan speed based on temperature, reducing noise and power consumption during low-load periods.
* **Locked Rotor Protection:** An internal electronic circuit that cuts or limits power if the blades are physically obstructed, preventing the motor coils from burning out.
* **Polarity Protection:** Protects the internal circuitry if the positive and negative leads are accidentally reversed during installation.
* **High Airflow-to-Size Ratio:** Designed with optimized blade geometry to move a high volume of air (CFM) even against high static pressure.
---
### 4. Application Use Cases
1. **Server Racks:** High-density cooling for 1U/2U server chassis.
2. **Network Switches:** Cooling internal ASICs and power supplies in telecommunications gear.
3. **Industrial Power Supplies:** Active cooling for high-wattage AC/DC converters.
---
- ⤷What is the maximum CFM (Airflow) rating for the MAH76FAG-R?
- ⤷ How does the PWM signal duty cycle affect the RPM of this fan?
- ⤷ What is the expected MTBF (Mean Time Between Failures) for the dual ball bearing system?