P002-002-R
AI

The **P002-002-R** is a specific power cable assembly manufactured by **Tripp Lite** (now part of Eaton). It is a short-length power cord primarily used for connecting networking hardware or computers to power distribution units (PDUs).
### 1. Technical Specifications
The electrical and physical characteristics of the P002-002-R are detailed in the table below:
| Feature | Specification |
| :--- | :--- |
| **Model Number** | P002-002-R |
| **Connector A** | NEMA 5-15P (Standard 3-prong North American Plug) |
| **Connector B** | IEC-320-C13 (Standard computer power connector) |
| **Length** | 2 Feet (0.61 Meters) |
| **Wire Gauge** | 18 AWG |
| **Ampere Rating** | 10 Amps |
| **Voltage Rating** | 125 Volts |
| **Jacket Type** | SJT |
| **Number of Conductors** | 3 |
---
### 2. Internal Electronic Components
While it appears to be a simple cable, the "electronic" integrity relies on specific material standards:
* **Conductors (Copper):** It contains three 18-gauge stranded copper wires (Line, Neutral, and Ground). Stranded copper is used to provide flexibility and resistance to fatigue from bending.
* **Insulation:** Each conductor is color-coded according to North American standards (Black for Hot, White for Neutral, Green for Ground) and encased in PVC insulation to prevent short circuits.
* **Molded Strain Relief:** The connectors are "molded," meaning the plastic housing is injected around the wire-to-terminal connection. This prevents mechanical stress from breaking the electrical connection inside the plug.
* **SJT Jacket:** The "Service Junior Thermoplastic" jacket is rated for 300V and is designed to withstand heat generated by 10A of continuous current.
---
### 3. Safety and Compliance
The "R" in the part number often signifies **Retail Packaging**, but the electrical build remains compliant with several industry safety standards:
1. **UL Listed:** Tested by Underwriters Laboratories for safety against fire and electric shock.
2. **RoHS Compliant:** Manufactured without hazardous materials like lead or cadmium.
3. **HPN/SJT Rating:** Ensures the outer jacket is flame retardant.
### 4. Common Use Cases
* **Server Racks:** The short 2ft length is ideal for connecting a server to a PDU located directly above or below it, reducing "cable clutter" and improving airflow.
* **Desktop PC to UPS:** Connecting a workstation to a Battery Backup system.
- ⤷What is the difference between 18 AWG and 14 AWG power cables?
- ⤷ Can the P002-002-R be used with high-wattage mining rigs?
- ⤷ What does the SJT jacket rating mean for indoor/outdoor use?