AI

The **VP2-0116-R** is a high-performance power inductor, part of the **Versa-Pac®** series manufactured by Eaton (formerly Bussmann/Coiltronics). These components are unique because they feature multiple tightly coupled windings, allowing them to be configured in various ways.
---
### 1. Key Technical Specifications
The "VP2" designation refers to the size and power rating within the family, while "0116" relates to the inductance and "R" denotes RoHS compliance.
| Parameter | Specification (Typical) |
| :--- | :--- |
| **Inductance (Parallel)** | ~6.7 µH (Typical) |
| **Inductance (Series)** | ~107.2 µH (Typical) |
| **Peak Current ($I_{sat}$)** | ~1.6A - 6.4A (Configuration dependent) |
| **DC Resistance (DCR)** | ~0.024 Ω per winding |
| **Number of Windings** | 6 independent windings |
| **Operating Temperature** | -40°C to +125°C |
| **Package Style** | Surface Mount (SMT) |
---
### 2. Physical Construction and Features
The VP2-0116-R is built using a **toroidal core** geometry which offers several electronic advantages:
* **Low Magnetic Leakage:** The toroidal shape keeps the magnetic field contained, reducing Electromagnetic Interference (EMI) with surrounding components.
* **High Efficiency:** The design minimizes core losses, making it suitable for high-frequency switching regulators.
* **Versatility:** With 6 separate windings, a single part can be used as an inductor, a 1:1 transformer, or a multi-tap autotransformer.
---
### 3. Common Circuit Applications
Because of its multi-winding nature, the VP2-0116-R is used in several specific power electronic roles:
#### A. Buck/Boost Converters
By connecting windings in series or parallel, engineers can fine-tune the inductance and current-carrying capacity to meet specific DC-DC conversion requirements.
#### B. SEPIC and Cuk Converters
These topologies require coupled inductors. The VP2 series is ideal here because the multiple windings share the same core, providing the necessary magnetic coupling in a single package.
#### C. Isolation Transformers
It can act as a 1:1 or 1:N transformer for low-power signal or gate drive isolation, provided the voltage levels remain within the insulation limits of the wire coating.
---
### 4. Configuration Diagram (Example)
```text
Winding 1: [1]--[ ]--[12]
Winding 2: [2]--[ ]--[11]
Winding 3: [3]--[ ]--[10]
Winding 4: [4]--[ ]--[9]
Winding 5: [5]--[ ]--[8]
Winding 6: [6]--[ ]--[7]
```
*Note: Terminals are paired. Connecting 1-2-3 and 12-11-10 puts windings in parallel to increase current capacity.*
- ⤷