The **W2TS-223-R2** is a specific model within the series of industrial industrial control components, typically categorized as a **Selector Switch** or **Pilot Device** assembly. Specifically, it is part of the 22mm diameter mounting range, which is the global standard for industrial control panels.
### 1. Component Specifications
The following table outlines the primary electrical and mechanical characteristics of the W2TS-223-R2.
| Specification | Details |
| :--- | :--- |
| **Mounting Diameter** | 22mm (Standard) |
| **Switch Action** | 3-Position Maintained (Stay-put) |
| **Contact Configuration** | 2 NO (Normally Open) |
| **Rated Voltage** | 600V AC/DC (Max Insulation) |
| **Thermal Current ($I_{th}$)** | 10A |
| **Ingress Protection** | IP65 / NEMA 4X (Water/Dust Resistant) |
| **Operator Type** | Standard Handle Selector |
---
### 2. Detailed Electronic Parts Breakdown
The unit is a modular assembly consisting of three core segments:
#### A. The Operator (Head)
* **Handle:** The physical lever turned by the user. The "223" code denotes a 3-position logic ($45^\circ$ throw).
* **Bezel:** Usually chrome or reinforced plastic, designed to secure the device to the panel door.
* **Mechanical Interlock:** A spring-loaded mechanism that ensures the switch clicks into place and stays there (Maintained action).
#### B. The Contact Block(s)
The "R2" suffix typically indicates the specific contact block arrangement:
* **2 NO Blocks:** It contains two separate contact units.
* **Contact Material:** Usually silver alloy to prevent oxidation and ensure high conductivity over thousands of cycles.
* **Terminal Screws:** Includes pressure plates for secure wiring of stranded or solid copper wires.
#### C. The Mounting Adapter
* This is the bridge between the operator and the contact blocks. It allows the blocks to be snapped on or removed without uninstalling the entire switch from the panel.
---
### 3. Truth Table (Logic States)
The electronic behavior of the 2 NO contacts based on the handle position:
| Handle Position | Left Contact (NO 1) | Right Contact (NO 2) |
| :--- | :--- | :--- |
| **Left ($45^\circ$)** | Closed (ON) | Open (OFF) |
| **Center ($0^\circ$)** | Open (OFF) | Open (OFF) |
| **Right ($45^\circ$)** | Open (OFF) | Closed (ON) |
---
### 4. Wiring Diagram Example
In a standard control circuit, the wiring would follow this logic:
```mermaid
graph LR
L1(Line Voltage) --> Input1[Contact 1 Terminal]
L1(Line Voltage) --> Input2[Contact 2 Terminal]
Input1 -- (Switch Left) --> Load1[Motor/Relay A]
Input2 -- (Switch Right) --> Load2[Motor/Relay B]
```
- ⤷