XCSMP79L5
AI

The **XCSMP79L5** is a safety interlock switch manufactured by **Telemecanique Sensors** (part of the Schneider Electric ecosystem). It is a compact, plastic safety switch designed specifically for monitoring the opening/closing of light guards or small protective covers on machinery.
---
### 1. Technical Specifications
The following table outlines the primary electrical and mechanical characteristics of the XCSMP79L5.
| Feature | Specification |
| :--- | :--- |
| **Contact Type** | 2 NC (Normally Closed) + 1 NO (Normally Open) |
| **Switching Method** | Slow-break, simultaneous |
| **Material** | PA (Polyamide) Plastic Body |
| **Cable Length** | 5 Meters (Pre-cabled) |
| **Voltage Rating** | 240V AC / 250V DC |
| **Current Rating (Ie)** | 1.5A at 240V (AC-15); 0.1A at 250V (DC-13) |
| **IP Rating** | IP67 (Dust tight and waterproof) |
---
### 2. Internal Electronic Design
The XCSMP79L5 is an electromechanical device. Its internal operation relies on physical contact movement rather than solid-state sensors.
* **Contact Configuration:** It features 3 poles. In a safety circuit, the **NC (Normally Closed)** contacts are typically wired to a safety relay to ensure that if the guard is opened, the machine circuit is broken immediately.
* **Positive Opening Operation:** The NC contacts are "positive opening," meaning that even if the contacts weld together, the mechanical force of opening the guard is designed to pull them apart (compliant with EN/IEC 60947-5-1).
* **Slow-break Mechanism:** The contacts move at the same speed as the actuator. This is standard for simple safety interlocks where "Snap Action" is not required.
---
### 3. Wiring Diagram Logic
The device is provided with a 5-meter molded cable. The internal wiring typically follows this color-coding logic (verify with specific datasheet before installation):
| Terminal Function | Typical Wire Colors |
| :--- | :--- |
| **NC Contact 1** | Red / Red-White |
| **NC Contact 2** | Blue / Blue-White |
| **NO Contact** | Orange / Orange-White |
---
### 4. Safety Level Integration
When integrated into a safety system, the XCSMP79L5 can help a machine reach the following safety ratings:
* **Category 4** (with an appropriate monitoring system/safety relay).
* **Performance Level (PL) e**.
* **SIL 3** (Safety Integrity Level).
---
- ⤷
How do I wire the XCSMP79L5 to a safety relay?
- ⤷ What is the difference between the XCSMP and the XCSPA series?
- ⤷ Can this switch be used in high-temperature environments?