Back Button MP020A-5 Datasheet HTML 9Page - Monolithic Power Systems MP020A-5 Datasheet HTML 10Page - Monolithic Power Systems MP020A-5 Datasheet HTML 11Page - Monolithic Power Systems MP020A-5 Datasheet HTML 12Page - Monolithic Power Systems MP020A-5 Datasheet HTML 13Page - Monolithic Power Systems MP020A-5 Datasheet HTML 14Page - Monolithic Power Systems MP020A-5 Datasheet HTML 15Page - Monolithic Power Systems MP020A-5 Datasheet HTML 16Page - Monolithic Power Systems MP020A-5 Datasheet HTML 17Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 21 page
background image
MP020A-5 – OFFLINE, PRIMARY-SIDE REGULATOR W/ CC/CV CONTROL AND 700V MOSFET
MP020A-5 Rev. 1.0
www.MonolithicPower.com
13
6/23/2017
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2017 MPS. All Rights Reserved.
Output Cable Compensation
To compensate for the secondary-side cable
voltage drop for a more precise output voltage,
the MP020A-5 has an internal output cable
compensation
circuit
(see
Figure
5).
The
internal ZCD sample can detect the duty of the
secondary-side diode. A low-pass filter converts
the duty signal to a DC voltage (VCP) that
changes as the load current varies.
VCP can be converted to a current signal drawn
from FB. The voltage drop on RUP helps the
output cable compensation. When the system
operates in the maximum load, the CP voltage
reaches a maximum of 2V.
CP
DS
+ -
VCP
*
*
T1
Vo
FB
RUP
RDOWN
VFCP
Figure 5: Output Cable Compensator
Determine
the
compensation
voltage
with
Equation (7):
P _ AU
SS
FCP
UP
3
5.6 D
N
V
2 R
360 10
N
 
(7)
Where
VFCP
is
the
secondary-side
compensation
voltage
drop,
DS
is
the
secondary-diode duty cycle in CC mode (0.4 for
the MP020A-5), RUP is the upper resistor of the
resistor divider, NS is the number of turns for the
secondary-side transformer windings, and NP_AU
is the number of transformer auxiliary winding
turns.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com