| Datenblatt-Suchmaschine für elektronische Bauteile |
|
MLX90621 Datenblatt(PDF) 2 Page - Melexis Microelectronic Systems |
|
|
|||||||||||||||||||||||||||||
MLX90621 Datenblatt(HTML) 2 Page - Melexis Microelectronic Systems |
|
2 / 44 page ![]() MLX90621 16x4 IR array Datasheet 39001090621 Page 2 of 44 Datasheet IR16x4 Rev 3.0 15 September 2016 General Description (continued) The results of the infrared sensor measurements are stored in RAM: • 15...18-bit result of IR measurement for each individual sensor (64 words) • 15…18-bit result of PTAT sensor Depending on the application, the external microcontroller can read the different RAM data and, based on the calibration data stored in the EEPROM memory, compensate for difference between sensors to build up a thermal image, or calculate the temperature at each spot of the imaged scene. These constants are accessible by the user microcontroller through the I2C bus and have to be used for external post processing of the thermal data. This post processing includes: • Ta calculation • Pixel offset cancelling • Pixel to pixel sensitivity difference compensation • Object emissivity compensation • Object temperature calculation The result is an image with NETD better than 0.1K RMS at 1Hz refresh rate. The refresh rate of the array is programmable by means of register settings or directly via I2C command. Changes of the refresh rate have a direct impact on the integration time and noise bandwidth (faster refresh rate means higher noise level). The frame rate is programmable in the range 0.5Hz…512Hz and can be changed to achieve the desired trade-off between speed and accuracy. The MLX90621 requires a single 2.6V…3.2V although the device is calibrated and performs best at VDD=2.6V. The MLX90621 is factory calibrated in following temperature ranges: • -40˚C…85˚C for the ambient temperature sensor • -50˚C…300˚C for the object temperature. NOTE: The sensor can detect higher temperatures, but is not calibrated for temperatures above 300°C. See Table 21 for configuration specific properties. Each pixel of the array measures the average temperature of all objects in its own Field Of View (called nFOV). It is very important for the application designer to understand that the accuracy of the temperature measurement is very sensitive to the thermal equilibrium isothermal conditions (there are no temperature differences across the sensor package). The accuracy of the thermometer can be influenced by temperature differences in the package induced by causes like (among others): Hot electronics behind the sensor, heaters/coolers behind or beside the sensor or by a hot/cold object very close to the sensor that not only heats the sensing element in the thermometer but also the thermometer package. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |