| Datenblatt-Suchmaschine für elektronische Bauteile |
|
LDS9003 Datenblatt(PDF) 10 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
LDS9003 Datenblatt(HTML) 10 Page - IXYS Corporation |
|
10 / 30 page ![]() LDS9003 / 9001 © 2009 IXYS Corp. 10 Doc. No. 9003/9001_DS, Rev. N1.0 Characteristics subject to change without notice Table 8: ΔPWM CorrectionCode Allocation Data bits Data bits 7 – 4 3 – 0 7 – 4 3 – 0 Register Address ΔPWM code for temperature, 0C Register Address ΔPWM code for temperature, 0C 50h, 60h, 70h -30 -35 58h, 68h, 78h 50 45 51h, 61h, 71h -20 -25 59h, 69h, 79h 60 55 52h, 62h, 72h -10 -15 5Ah, 6Ah, 7Ah 70 65 53h, 63h, 73h 0 -5 5Bh, 6Bh, 7Bh 80 75 54h, 64h, 74h 10 5 5Ch, 6Ch, 7Ch 90 85 55h, 65h, 75h 20 15 5Dh, 6Dh, 7Dh 100 95 56h, 66h, 76h 30 25 5Eh, 6Eh, 7Eh 110 105 57h, 67h, 77h 40 35 5Fh, 6Fh, 7Fh 120 115 Table 9: ΔPWM Codes Codes vs. Number of Adjustment Steps Number of steps Binary Code Number of steps Binary Code Number of steps Binary Code Number of steps Binary Code Not Valid 1000 -4 1100 0 0000 4 0100 -7 1001 -3 1101 1 0001 5 0101 -6 1010 -2 1110 2 0010 6 0110 -5 1011 -1 1111 3 0011 7 0111 PROGRAMMING EXAMPLES Operation Register Address Register Data Command (hex) Disable Temperature De-rating (DT_Adjust_disable) 1Eh 04h XX 1E 04 Re-Enable Temperature De-rating 1Eh 00h XX 1E 00 Short/open LED diagnostic request 19h 20h XX 19 20 Read out LED short to GND status 1Ch XX 1C YY Read out LED short to VIN/open status 1Dh XX 1D YY Set Standby Mode 1Fh 40h XX 1F 40 Resume normal operation from standby mode 1Fh 00h XX 1F 00 Calibration request (conduct temperature calibration) 1Fh 10h XX 1F 10 Set LEDs in shutdown mode at junction temperature above 100 0 C 4Ah 1Bh XX 4A 1B Set Ta-Tj offset for LED and Si Diode to -20ºC 49h CCh XX 49 CC Software Reset (to default values) and/or clear of all registers 1Fh 80h XX 1F 80 Note: XX – The LD9003/9001 I 2C customer-selected slave address followed by binary 1 for write command, i.e. if I2C slave address is 001 0001 (see Table 8), XX = 0010 0011 (bin) = 23h YY – The 90003/9001 I 2C customer-selected slave address followed by binary 0 for read command, i.e. if I2C slave address is 001 0001 (see Table 8), YY = 0010 0010 (bin) = 22h |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |