| Datenblatt-Suchmaschine für elektronische Bauteile |
|
MAS6503 Datenblatt(PDF) 27 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6503 Datenblatt(HTML) 27 Page - Micro Analog systems |
|
27 / 34 page ![]() DA6503.005 14 December 2016 27 (34) APPLICATION INFORMATION VDD Level Monitoring Configuration The MAS6503 has VDD level monitoring feature to measure supply voltage level which is useful especially in battery operated systems. In systems in which VDD can vary the VDD level monitoring could be also used to compensate VDD dependency. The VDD level monitoring measurement is started by writing configuration data to the measurement control registers 1 (E2/62HEX) and 2 (E3/63HEX). In the proper configuration it is necessary to disable both regulator (ENREG=0) and offset (ENOFS=0) and select the widest input signal conversion range 373mV (ISCR=00) and the VDD level monitoring measurement (PTS=01). Typically the smallest over sampling ratio (OSR) selection 256 offers sufficient resolution for the VDD level monitoring. VDD level monitoring model The VDD level monitoring model for output code is following. VDD b a CODEFS CODE The output has inverse relationship to supply voltage VDD. The OSR selects full scale output code range value CODEFS. See Electrical Characteristics for CODEFS at different OSR values. The typical VDD level monitoring model parameter values a and b are as follows. a=1.7064 b=2.9123 Note that these parameter values are subject to about two percent variations. The supply voltage VDD can be solved from the output result as follows. CODEFS CODE a b VDD Figure 9 presents typical output code as function of supply voltage at OSR=256 (CODEFS=227328). Figure 10 present supply voltage as function of output code at OSR=256 (CODEFS =227328). 20000 50000 80000 110000 140000 170000 200000 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 VDD [V] 1.7 1.9 2.1 2.3 2.5 2.7 2.9 3.1 3.3 3.5 3.7 3.9 4.1 0 50000 100000 150000 200000 250000 CODE [LSB] Figure 9. CODE(VDD) at VDD level monitoring Figure 10. VDD(CODE) at VDD level monitoring |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |