10 / 35 page ![]() V 1.2 10 2016/04/27 ES251 2000 Counts DMM 1.3. Current Measurement For Multi-meter ES251 has 3 automatic current measurement modes for multi-meter. The following table summarizes the full-scale range of each mode. When ES251 operates in the current measurement modes for multi-meter, it takes high input from pin IVS, low input from pin SGND and reference voltage from calibration scheme. Mode FC1~4 Full Scale Input Terminal CAL Automatic1 1,1,0,1 200.0µA / 2000µA IVS V.S. SGND AC 200uA 3 Automatic2 1,1,1,1 20.00mA / 200.0mA IVS V.S. SGND AC 20mA 3 Automatic3 0,0,0,0 2.000A /20.00A 2 IVS V.S. SGND Yes Note: 1. Connect Clamp (pion39) to V- will disable the “µ2” / ”m2” symbol on LCD panel. 2. Connect ASEL (pin43) to V- will set maximum readings of input for Automatic3 mode to 10.00A. 3. DCuA/DCmA use the same configuration as DCV mode. AC higher range use the same configuration as ACV mode. 1.4. Current Measurement For Clamp-meter ES251 has 2 automatic and 4 manual current measurement modes for Clampmeter. The following table summarizes the Full-Scale range of each mode. When ES251 operate in the automatic modes and the manual mode1~4, it takes high input from IVS pin, low input from SGND and reference voltage from VR_CLAMP. Mode FC1~4 1CLAMP Range Max full scale Input Terminal CAL Automatic1 1,1,0,1 0 200.0A / 2000A 2 20/200 mV IVS V.S. SGND Yes 4 Automatic2 1,1,1,1 0 20.00A / 999.9A 20/1000 mV IVS V.S. SGND Yes 4 Manual1 1,1,0,0 X 2.000A 600 mV IVS V.S. SGND Yes Manual2 1,0,0,0 X 20.00A 600 mV IVS V.S. SGND Yes Manual3 1,0,1,0 X 200.0A 600 mV IVS V.S. SGND Yes Manual4 1,0,0,1 X 1000A or 2000A 2 100 or 200 mV IVS V.S. SGND Yes Note: 1. Connect CLAMP to V- will disable the “µ2” / ”m2” symbol on LCD panel. 2. Connect ASEL to V- will set maximum of input for Automatic1 & Manual4 modes to 1000A. 3. In DC current modes for clamp-meter, ES251 provides Zero Function (pin70) for offset removing. 4. AC Lower range calibration use the same configuration as Manual3 ACA mode. AC Higher range calibration use the same configuration as Manual4 ACA mode. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |