20 / 27 page ![]() Datasheet TEK.COM 20 Threshold Level Accuracy 89 Threshold Range Threshold Resolution Accuracy ±(% of reading) 2 Year, T CAL ±5°C 100 mV to 700 V 0.05% 1.0% Frequency and Period Characteristics Measurement Method Reciprocal counting technique. Aperture 10 ms to 273 ms; default is 10 ms. Typical Reading Rates, 60 Hz (50 Hz) Operation 90, 91, 92, 93 NPLC Digits Functions: DC Voltage (10 V), 2-wire Ohms ( ≤10 kΩ), DC Current (1 mA) Functions: 4-wire ohms ( ≤1 kΩ), 4-wire/3-wire RTD Functions: Thermistor Functions: Dry Circuit ( ≤1 kΩ) Measurements Into Buffer Measurements Into Computer Measurements Into Buffer Measurements Into Computer Measurements Into Buffer Measurements Into Computer Measurements Into Buffer Measurements Into Computer 1 7½ 59.8 (49.8) 58 (48) 29 (24) 28 (24) 57 (48) 57 (48) 27 (23) 26 (22) 0.2 6½ 295 (240) 250 (210) 128 (109) 119 (100) 230 (200) 230 (200) 100 (89) 96 (85) 0.06 5½ 965 (810) 950 (800) 310 (280) 315 (280) 900 (750) 900 (750) 190 (180) 190 (180) 0.006 4½ 7500 (6700) 7300 (6500) 750 (730) 740 (720) 6800 (6000) 6800 (6000) 295 (290) 295 (290) 0.0005 3½ 26000 (26000) 24000 (24000) 860 (860) 860 (860) 18000 (18000) 18000 (18000) 310 (310) 310 (310) Detector Bandwidth (Hz) Digits Functions: ACV, ACI Measurements Into Buffer Measurements Into Computer 3 6½ 0.5 (0.5) 0.5 (0.5) 30 6½ 3.3 (3.3) 3.3 (3.3) 300 94 6½ 59.8 (49.8) 55 (46) 300 94 3½ 26200 (26200) 24500 (24500) Digitize, Typical Sampling Rate Digits Resolution Measurements Into Computer 93 10 kS/s 5½ 18 9700 20 kS/s 4½ 16 19000 50 kS/s 4½ 16 44400 100 kS/s 4½ 15 80000 1 MS/s 3½ 12 108000 NOTES 89. Threshold range is voltage RMS and threshold level voltage peak. Specified with 1kHz square wave. 100V and 700V threshold ranges guaranteed by design. 90. Reading speeds for autozero off, fixed range, autodelay off. Offset compensation off and open lead detector off where applicable. 91. Buffer measurements: For <0.2 PLC, multisample, single buffer transfer binary reading only. 92. PC measurements: For 1 and 0.2 PLC single reading and single transfer to computer (USB). 93. Reading rates using factory default operating conditions and autorange off, autodelay off. Speeds include measurement and data transfer out of the USB. ≥1000 readings with binary transfer over USB. 94. For bandwidth 300Hz, autozero off, 6½ digits at 1 PLC, 3½ digits at 0.0005 PLC. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |