| Datenblatt-Suchmaschine für elektronische Bauteile |
|
TLC3544CPWRG4 Datenblatt(PDF) 23 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLC3544CPWRG4 Datenblatt(HTML) 23 Page - Texas Instruments |
|
23 / 40 page ![]() TLC3544, TLC3548 5-V ANALOG, 3-/5-V DIGITAL, 14-BIT, 200-KSPS, 4-/8-CHANNELS SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH 0-5 V (PSEUDODIFFERENTIAL) INPUTS SLAS266C – OCTOBER 2000 – REVISED MAY 2003 23 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 operation cycle timing (continued) Table 3. Operation Options MODE CONVERSION IS INITIATED BY MODE CS FS CSTART 00 1. Issue new Select/Read operation to read data and start new conversion. 2. Reconfigure the device. 1. Issue new Select/Read operation to read data and start new conversion. 2. Reconfigure the device. 1. Issue new CSTART to start next conversion; old data lost. 2. Issue new Select/Read operation to read data—Issue new CSTART to start new conversion. 3. Reconfigure the device. 01 1. Read FIFO—Select Channel—Start new conversion. Channel must be selected after FIFO READ. 2. Select Channel—Start new conversion (old data lost) 3. Configure device again. 1. Read FIFO—Select Channel—Start new conversion. Channel must be selected after FIFO READ. 2. Select Channel—Start new conversion (old data lost) 3. Configure device again. 1. Read FIFO—Select channel—Start new conversion. Channel must be selected after FIFO READ. 2. Start new conversion (old data lost) with existing setting. 3. Configure device again. 10 1. Read FIFO—Start new conversion with existing setting. 2. Configure device—New conversion (old data lost) 1. Read FIFO—Start new conversion with existing setting. 2. Configure device—New conversion (old data lost) 1. Read FIFO—Arm Period—Start new conversion with existing setting 2. Configure device—Arm Period—New conversion (old data lost) 11 1. Read FIFO—Start new conversion with existing setting. 2. Start new conversion with the existing setting. 3. Configure device—Start new conversion with new setting. 1. Read FIFO—Start new conversion with existing setting 2. Start new conversion with the existing setting. 3. Configure Device—Start new conversion with new setting. 1. Read FIFO—Arm Period—Start new Conversion with existing setting 2. Start new conversion with existing setting. (old data lost) 3. Configure device—Arm Period—New conversion with new setting. operation timing diagrams The FIFO read and write CFR are nonconversion operations. The conversion operation performs one of four types of conversion: mode 00, 01, 10, and 11 Write Cycle (WRITE CFR Command): Write cycle does not generate EOC or INT, nor does it carry out any conversion. 1 2 3 5 4 6 7 13 14 15 16 1 ID15 1D14 ID13 1D12 12 ID15 ID11 ID10 ID9 ID4 ID3 ID2 ID1 ID0 OR CS FS SDI INT EOC SDO Hi-Z Note: Signal May Not Exist. Don’t Care Figure 9. Write Cycle, FS Initiates Operation |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |