| Datenblatt-Suchmaschine für elektronische Bauteile |
|
ACS732KMA Datenblatt(PDF) 3 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
ACS732KMA Datenblatt(HTML) 3 Page - Allegro MicroSystems |
|
3 / 22 page ![]() 1 MHz Bandwidth, Galvanically Isolated Current Sensor IC in SOIC-16 Package ACS732KMA and ACS733KMA 3 Allegro MicroSystems 955 Perimeter Road Manchester, NH 03103-3353 U.S.A. www.allegromicro.com Terminal List Table Number Name Description 1,2,3,4 IP+ Positive terminals for current being sensed; fused internally. 5,6,7,8 IP– Negative terminals for current being sensed; fused internally. 9 PROGRAM Programming input pin for factory calibration. Connect to ground for best ESD performance. 10, 11 GND Device ground terminal. 12 VIOUT Analog output signal. 13 FAULT Overcurrent Fault output. Open drain. 14, 15 VCC Device power supply terminal. 16 VOC Set the overcurrent fault threshold via external resistor divider on this pin. Package MA, 16-Pin SOICW Pinout Diagram PINOUT DIAGRAM AND TERMINAL LIST TABLE 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 IP+ IP+ IP+ IP+ IP– IP– IP– IP– VOC VCC VCC FAULT VIOUT GND GND PROGRAM ISOLATION CHARACTERISTICS Characteristic Symbol Notes Rating Unit Dielectric Strength Test Voltage VISO Agency type-tested for 60 seconds per UL 60950-1 (edition 2) and UL 62368 (edition 1). Production tested at 3000 VRMS for 1 second, in accordance with UL 60950-1 (edition 2) and UL 62368 (edition 1). 4800 VRMS Working Voltage for Basic Isolation VWVBI Maximum approved working voltage for basic (single) isolation according to UL 60950-1 (edition 2) and UL 62368 (edition 1). 1480 VPK 1047 VRMS or VDC Working Voltage for Reinforced Isolation VWVRI Maximum approved working voltage for reinforced isolation according to UL 60950-1 (edition 2) and UL 62368 (edition 1). 730 VPK 517 VRMS or VDC Clearance Dcl Minimum distance through air from IP leads to signal leads. 7.5 mm Creepage Dcr Minimum distance along package body from IP leads to signal leads 7.9 mm Distance Through Insulation DTI Minimum internal distance through insulation 90 μm Comparative Tracking Index CTI Material Group II 400 to 599 V ESD RATINGS Characteristic Symbol Test Conditions Value Unit Human Body Model VHBM Per AEC-Q100 ±12 kV Charged Device Model VCDM Per AEC-Q100 ±1 kV |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |