| Datenblatt-Suchmaschine für elektronische Bauteile |
|
W2PP-239N-R2/N Datenblatt(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
W2PP-239N-R2/N Datenblatt(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: W2PP W2PP SPECIFICATIONS ES-5534 Rev.12 Page 2/4 http://www.m-system.co.jp/ RELATED PRODUCTS • Clamp-on pulse sensor (model: CLSP) GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output 1 to output 2 to power Frequency range: Input and output are the same. Chattering protection: Filter provided for mechanical contact input Input pulse sensing: DC coupled INPUT SPECIFICATIONS Excitation: 12 V DC @30 mA; shortcircuit protection ■ Open Collector Maximum frequency: 10 kHz Pulse width time requirement: 10 μsec. min. for ON and OFF Sensing: Approx. 12 V DC @3 mA ON/OFF level: ≤ 600 Ω / 1.8 V for ON, ≥ 100 kΩ / 3.5 V for OFF ■ Mechanical Contact Maximum frequency: 30 Hz Pulse width time requirement: 10 msec. min. for ON and OFF Sensing: Approx. 12 V DC @3 mA ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2.5 V for OFF ■ Voltage Pulse Maximum frequency: 10 kHz Pulse width time requirement: 10 μsec. min. for high and low levels Waveforms: Square or sine Hi/Lo level: 2 – 50 V for high level; ≤1 V for low level Input impedance: 10 kΩ min. ■ Clamp-on Pulse Sensor CLSP Maximum frequency: 50 000 pulses/hour ON/OFF level: ≤ 400 Ω / 1.3 V for ON, ≥ 200 kΩ / 12 V for OFF OUTPUT SPECIFICATIONS ■ Low Frequency Open Collector: 50 V DC @100 mA (resistive load) Maximum frequency: 30 Hz Timer: Limits within 75 ±25 msec. for wider than 75 msec. pulses ON time for output logic non-inverted OFF time for output logic inverted (When the low frequency open collector or the dry contact AC/DC switch is selected as one of the outputs, the timer is applied also to the other output.) Saturation voltage: 0.5 V DC ■ High Frequency Open Collector: 50 V DC @100 mA (resistive load) Maximum frequency: 10 kHz Saturation voltage: 0.5 V DC ■ Voltage Pulse Maximum frequency: 10 kHz High level: Rating (5, 12 or 24 V) ±10 % Low level: ≤ 0.5V Load resistance: ≥ 250 Ω for 5 V ≥ 600 Ω for 12 V ≥ 1200 Ω for 24 V, output 1 ≥ 2400 Ω for 24 V, output 2 ■ Dry Contact AC/DC Switch 132 V AC @200 mA (cos ø = 1) 30 V DC @200 mA (resistive load) Maximum frequency: 30 Hz Timer: Limits within 75 ±25 msec. for wider than 75 msec. pulses ON time for output logic non-inverted OFF time for output logic inverted (When the low frequency open collector or the dry contact AC/DC switch is selected as one of the outputs, the timer is applied also to the other output.) Saturation voltage: 3 V DC INSTALLATION Power Consumption •AC: Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 240 V •DC: Approx. 4 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 200 g (0.44 lb) PERFORMANCE Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output 1 to output 2 to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |