26 / 39 page ![]() – – – – 46 47 ACK on Wake - Address = 0x59; NV Address = 0x0E When the module powers up and is ready for operation, it can output an acknowledge (ACK) character (0x06) on the TXD line. This indicates that the module is ready to accept data and commands. Setting this register to 0x00 disables the ACK, 0x01 enables the ACK. The default value is 0x01. Figure 49 shows examples of the commands and Figure 50 shows the available values. Figure 49: 250 Series ACK on Wake Command and Response 250 Series ACK on Wake Register Settings V1 Mode 0x00 Disable ACK 0x01 Enable ACK Figure 50: 250 Series ACK on Wake Register Settings 250 Series ACK on Wake Read Command Read Response Header Size Escape Address ACK Address Value 0xFF 0x02 0xFE 0x59 0x0E 0x06 0x59 0x0E V1 Write Command Header Size Address Value 0xFF 0x02 0x59 0x0E V1 Operating Mode - Address = 0x58; NV Address = 0x0D The value in the regOPMODE register sets the operating mode of the transceiver. If the module remains properly powered, and is awakened from a low power mode properly, the volatile registers retain their values when awakened. If the volatile registers become corrupted during low power, a software reset is forced and the module reboots. Awake mode is the normal operating mode. This is the only mode in which the RF circuitry is able to receive and transmit RF messages. Standby leaves the RF oscillator circuit operating for faster wakeup, whereas Sleep does not. One byte of 0x0F to the module’s RXD line at the current baud rate wakes the modules. Deep Sleep mode disables all circuitry on-board the module. This is the lowest-power mode available for the module. A low pulse on the RESET line of at least 15µs wakes the module. The module begins the wake process once the RESET line is returned high. Please see the Low Power States section for more details. Figure 47 shows examples of the commands and Figure 48 shows the available values. Figure 47: 250 Series Operating Mode Command and Response 250 Series Operating Mode Register Settings V1 Mode 0x00 Awake Mode 0x01 Sleep Mode 0x02 Standby Mode 0x03 Deep Sleep Mode Figure 48: 250 Series Operating Mode Register Settings 250 Series Operating Mode Read Command Read Response Header Size Escape Address ACK Address Value 0xFF 0x02 0xFE 0x58 0x0D 0x06 0x58 0x0D V1 Write Command Header Size Address Value 0xFF 0x02 0x58 0x0D V1 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |