| Datenblatt-Suchmaschine für elektronische Bauteile |
|
CJ1H-CPU67H-R Datenblatt(PDF) 3 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
CJ1H-CPU67H-R Datenblatt(HTML) 3 Page - Omron Electronics LLC |
|
3 / 10 page ![]() CJ1G-CPU4 @P 3 Specifications Item Specification Product name Loop-control CPU Unit Model numbers CJ1G-CPU @@P Data exchange method with CPU Unit Words in Auxiliary Area in CPU Unit Loop Controller → CPU Unit: Operation status, PV error input ON, MV error input ON, occurrence of execution error, function block database error, cold start ready for hot start command, flash memory backup in progress, function blocks changed, etc. CPU Unit → Loop Controller: Hot/cold start command at power ON User allocations in I/O memory User memory tables used to allocate function block ITEM data for user-specified memory in the CPU Unit (CIO, Work, HR, DM, or EM Area (bank 0, but also banks 1 to 12 for Ver. 3.0 or later)). EM Area (bank number) allocations (for SCADA software) HMI function used allocate function block ITEM data for Control, Operation, External Controller, and System Common blocks in the specified bank of the EM Area in the CPU Unit. The real PV in calibration mode can be allocated (Ver. 3.0 or later). Setting None Indicators Loop-control CPU Units: 2 LEDs (RUN and ready) Super capacitor backup data All function block data (including Step Ladder Program commands), stored error log data Super capacitor backup time CJ Series (CJ1G-CPU @@P): 5 min at 25°C (Backed up by the Battery in the CPU Unit.) Data stored in flash memory Function block data Backup from RAM to flash memory Executed from CX-Process Tool (as required). Recovery from flash memory to RAM Automatic at power ON if startup mode is set for a cold start, or executed from CX-Process Tool (as required). Influence on CPU Unit cycle time Loop-control CPU Unit (CJ1G-CPU @@P): 0.8 ms max. (Depends on function block contents.) Current consumption (supplied from Power Supply Unit) Loop-control CPU Unit: 1.06 A at 5 VDC Note: Increased by 150 mA when NT-AL001 Link Adapter is used. Standard accessories None |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |