| Datenblatt-Suchmaschine für elektronische Bauteile |
|
BW250RAM Datenblatt(PDF) 26 Page - Fuji Electric |
|
|
|||||||||||||||||||||||||||||
BW250RAM Datenblatt(HTML) 26 Page - Fuji Electric |
|
26 / 93 page ![]() Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/26 Terminal position Applicable breaker type Code Blank Blank SB SF S3 S4 S5 S6 S7 S8 Line Screw Flat teminal Block terminal Flat teminal Screw Flat teminal Screw Block terminal Flat teminal Block terminal Load Screw Flat teminal Block terminal Flat teminal Flat terminal Screw Block terminal Screw Block terminal Flat terminal BW100, 125, 250 – BW50 – – – – – – BW400, 630, 800 – – – – – – Molded Case Circuit Breakers G-TWIN series Wire size and terminal n Notes on wiring (global series) Notes on connecting wires (conductors) • Connect wires to the UL breaker according to NEC (National Electric Code) or CEC (Canadian Electrical Code) Part 1. • Use 75°C copper wires for wiring. UL-certified or CSA- certified wires are recommended. • If a large current (for example, a short-circuit current) flows, it causes a huge electromagnetic force between wires. Therefore, be sure to secure the wires sufficiently. • Re-tighten terminal screws periodically. Block terminal connection • Choose from the stranded wires shown in Table. Wire size: AWG or MCM [mm2] No. of wires stranded 14 to 2 [2.1 to 33.6] 7 1 to 4/0 [42.4 to 107.2] 19 250 to 500 [127 to 250] 37 Values in [ ] are those converted from AWG or MCM sizes to mm2. * See the instruction manual that comes with the breaker for more details. Precautions • Two wires of different sizes cannot be connected to the same block terminal. • Be sure to use stranded wires according to Table "Number of wires stranded." • Multi-conductor wires cannot be connected. • Do not solder wires together. Wire size and crimp terminal • Crimp terminal connection MCCB Rated current (A) Applicable crimp terminal 75˚C wire Connectable wire size (AWG) Tightening torque (N•m) Type of screw head and size (mm) J.S.T Mfg. Co., Ltd. Nichifu Co., Ltd. Daido Solderless Terminal Mfg. Co., Ltd. 75˚C wire BW50RAGU 3 R2-5 R2-5M R2-5 2-S5, 2-5 14AWG 2.3-2.8 Cross/straight slotted pan-head screw M5 x 14 5 10 15 20 R5.5-5 R3.5-5S, R3.5-5L, 5.5-6N, R5.5-5S, R5.5-5 3.5-5, 5.5-S5, 5.5-5, 5.5-L5 12AWG 30 10AWG 40 R8-5 R8-5S, R8-5 8-S5, 8-5 8AWG 50 BW100EAGU 60 R14-8 R14-8S, R14-8 R14-S8, R14-8 6AWG 5.5-7.5 Cross/straight slotted pan-head screw M8 x 15 75 22-S8 R22-8S, R22-8 R22-S8, 22-8 4AWG 100 38-S8 R38-8S 38-S8 3AWG BW125JAGU BW125RAGU 15 R2-8 R2-8 2-8, 2-B8 14AWG 5.8 (5.3-6.4) Cross/straight slotted pan-head screw M8 x 16 20 5.5-S8, R5.5-8 R3.5-8, R5.5-8 3.5-8, 5.5-8 12AWG 30 R5.5-8 5.5-8 10AWG 40 8-8NS, R8-8 R8-8 8-8 8AWG 50 60 14-8NS, 14-S8, R14-8 R14-8S, R14-8 14-S8, 14-8 6AWG 70 22-S8, R22-8, CB22-S8 R22-8S, R22-8, CB22-8S 22-S8, 22-8, CB22-8 4AWG 75 80 90 38-S8 R38-8S 38-S8 3AWG 100 125 1AWG BW250EAGU BW250JAGU BW250RAGU 125 38-S8, R38-8 R38-8S, R38-8 38-S8, 38-8 1AWG 10.5 (8-13) Hexagon socket head bolt M8 x 16 150 60-S8, R60-8 R60-8, CB60-8, CB60-8S 60-8, CB60-8 1/0AWG 175 70-8 R70-8 70-8 2/0AWG 200 CB80-S8 CB80-8 3/0AWG 225 CB100-S8 CB100-8 4/0AWG 250 CB150-S8 CB150-8 CB150-8 250MCM Notes: • AWG/MCM is the UL approved wire unit. • The allowable temperature of wire is 75˚C. (UL CSA approved) • Be sure to use UL-certified or CSA-certified crimp tools commercially available. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |