4 / 11 page ![]() (b) Fuse Input +Vin -Vin Schottky Barrier Diode Fig.2.2 Connecting a Reverse Voltage Protection Circuit ¡ Basically, SU/SUC/SUT series do not need any external capaci- tor. However, if you want to further reduce the output ripple noise, connect an electrolytic capacitor or a ceramic capacitor Co to the output pin terminal as shown below. Co Co Co COM Load Load Load SUW/SUCW SUS/SUCS +Vout -Vout -Vout +Vout Fig.2.3 Connecting Example of an External Capacitor to the Output Side Table 2.2 Recommended Capacitance of External Capacitor on the Output Side [ F] Model Output Voltage(V) SU/SUC1R5 SU/SUC3/SUT3 SU/SUC6/SUT6 SU/SUC10/SUT10 3.3 1 - 100 1 - 220 1 - 220 1 - 220 5 1 - 100 1 - 220 1 - 220 1 - 220 12 1 - 100 1 - 100 1 - 100 1 - 100 15 1 - 100 1 - 100 1 - 100 1 - 100 * If you use a ceramic capacitor, keep the capacitance within the range between about 0.1 to 10 F. * Please adjust the capacitance in light of the effect you want to achieve. * If you need to use an external capacitor whose capacitance ex- ceeds the range provided in Table 2.2, please contact us. ¡ If the distance between the output and the load is long and there- fore the noise is created on the load side, connect a capacitor externally to the load as shown below. Load Input +Vin -Vin +Vout -Vout 3 Series/Parallel Operation 3.1 Series Operation ¡ You can use the power supplies in series operation by wiring as shown below. In the case of (a) below, the output current should be lower than the rated current of a power supply with the lowest rated current among power supplies that are serially connected. Please make sure that no current exceeding the rated current flows into a power supply. (a) D1 - D4 : Use a schottky barrier diode with low forward voltage. D1, D2 : Use a schottky barrier diode with low forward voltage. D2 D1 + - - + Power Supply Power Supply 12V or more Power Supply Power Supply D4 D2 + - - + 5V or less D1 D3 (b) Power Supply Power Supply + - - + Fig.3.1 Series Operation 3.2 Redundancy Operation ¡ You can use the power supplies in redundancy operation by wiring as shown below. Power Supply Power Supply I2 I1 I3 - + + - Fig.3.2 Redundancy Operation ¡ Even a slight difference in output voltage can affect the balance between the values of I1 and I2. Please make sure that the value of I3 does not exceed the rated current of a power supply. I3 [ Rated Current Value DC-DC Converters PCB Mount Type Instruction Manual SU.SUC/SUT-54 June 26, 2020 |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |