| Datenblatt-Suchmaschine für elektronische Bauteile |
|
WLG2-LDAS Datenblatt(PDF) 23 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
WLG2-LDAS Datenblatt(HTML) 23 Page - Omron Electronics LLC |
|
23 / 52 page ![]() WL-N/WLM-N 23 Ratings Screw Terminals Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current. * Refer to the rating of a General-purpose / Weather-proof Switches type for the rating of a high-sensitivity overtravel type. * For high-sensitivity switches. Characteristics Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models. *1. The values are calculated at an operating temperature of +5 °C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Durability is 10,000,000 operations min. for high-sensitivity models. *3. Durability is 500,000 operations min. for high-sensitivity models. 500,000 operations min. for weather-proof models. Contact your OMRON representative for information on Airtight Switches. *4. Switches with Connectors: 1,500 V. Spatter-prevention Switches Item Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO WL @-LES-N (Without high-sensitivity overtravel models) AC 125 250 10 10 3 2 1.5 1 10 10 5 3 2.5 1.5 WL @-LDS-N (Without high-sensitivity overtravel models) AC 115 10 3 1.5 10 5 2.5 DC 12 24 115 10 6 0.8 6 4 0.2 3 3 0.2 10 6 0.8 6 4 0.2 Inrush current NC 30 A max.(15 A max. *) NO 20 A max.(10 A max. *) Minimum applicable load 5 VDC 1 mA, resistive load, P level Degree of protection IP67 Durability *1 Mechanical 15,000,000 operations min. *2 Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) *3 Operating speed 1 mm/s to 1 m/s (in case of WLCA2-LDS-N) Operating frequency Mechanical 120 operations/minute min. Electrical 30 operations/minute min. Rated frequency 50/60 Hz Insulation resistance 100 M Ω min. (at 500 VDC) Contact resistance 25 m Ω max. (initial value for the built-in switch when tested alone) Dielectric strength Between terminals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min Between currentcarrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction 1,000 m/s2 max. Malfunction 300 m/s2 Ambient operating temperature -10 to +80 °C (with no icing) Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (in case of WLCA2-LDS-N) |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |