Back Button SEN5X Datasheet HTML 5Page - Sensirion AG Switzerland SEN5X Datasheet HTML 6Page - Sensirion AG Switzerland SEN5X Datasheet HTML 7Page - Sensirion AG Switzerland SEN5X Datasheet HTML 8Page - Sensirion AG Switzerland SEN5X Datasheet HTML 9Page - Sensirion AG Switzerland SEN5X Datasheet HTML 10Page - Sensirion AG Switzerland SEN5X Datasheet HTML 11Page - Sensirion AG Switzerland SEN5X Datasheet HTML 12Page - Sensirion AG Switzerland SEN5X Datasheet HTML 13Page - Sensirion AG Switzerland Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 30 page
background image
www.sensirion.com
Version 2 – D1 – March 2022
9/30
2.5 Recommended and Absolute Maximum/Minimum Operating and Storage Conditions
The SEN5x contains different sensing components with different recommended operating and storage ranges. To ensure
an optimal performance of the SEN5x, the “SEN5x Handling Instructions” as well as the “SEN5x Mechanical Assembly
and Design-in Guidelines” need to be followed.
2.5.1 SEN54 and SEN55
Table 6 and Figure 2 show the recommended operating and storage conditions in which all the sensing components of
the SEN54 and SEN55 show best performance, as well as absolute maximum/minimum conditions which must not be
exceeded. Gas sensing specifications are guaranteed only when the SEN54 and SEN55 are operated and stored under
the recommended conditions given in Table 6.
Exposure to conditions outside the recommended range may temporarily reduce sensor performance (reversible RH
drift, reduced RH, T, gas, PM accuracy). Exposure to conditions outside absolute maximum/minimum range may lead
to permanently reduced sensor performance (gas sensitivity drift) or cause permanent damage to the device.
The sensor must not be exposed towards condensing conditions at any time.
Condition
Parameter
Recommended
Absolute Maximum/Minimum
Unit
Min.
Max.
Min.
Max.
Operating conditions
Temperature
10
40
-10
50
°C
Relative humidity
20
80
0
90 (non-condensing) % RH
Storage conditions
Temperature
10
30
-40
70
°C
Relative Humidity
20
60
0
80 (non-condensing) % RH
Table 6 Recommended and absolute maximum/minimum operating and storage conditions for SEN54 and SEN55.
Figure 2 Recommended and absolute maximum/minimum operating and storage conditions for SEN54 and SEN55.
Operating
0
20
40
60
80
100
-40
0
40
80
-20
20
60
Temperature / °C
0
20
40
60
80
100
-40
Storage
0
40
80
-20
20
60
Temperature / °C
Recommended range
Absolute maximum/minimum range



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com