7 / 15 page ![]() Board Mount Pressure Sensor AMS 5915 SERIES © 2022, Analog Microelectronics GmbH www.analog-micro.com Datasheet AMS 5915 – Rev. 4.0 7/15 INITIAL OPERATION Electrical Connection The electrical connection of AMS 5915 sensors is typically made by soldering them directly on a printed circuit board or by mounting them on a suitable socket. The basic circuit of the AMS 5915 sensor is shown in Figure 2. To read data from the digital output, it is enough to connect PIN1 (GND), PIN2 (VCC) and the I2C- bus lines to PIN3 (SDA) and PIN4 (SCL). Pins 5 to 8 are internally not connected and can be left unconnected. Important: For I2C-bus communication, each bus line (SCL and SDA) has to be connected to the positive supply voltage (pin Vcc or +3.3 V) via a pull-up resistor. Please add pull-up resis tors (4.7 kΩ are recommended) to your bus line if they are not integrated in the I2C-master. Pressure Connection The pressure connection is established by mounting hoses / flexible tubing on the sensor ’s metal pressure ports or by sealing the pressure ports of the N-type package via O-rings to a suitable flange. Depending on the sensor type and the type of measuring pressure, one or two of the pressure ports are connected to the measuring medium / volume, as described in the table below: wherein p1 = pressure at port 1 and p2 = pressure at port 2. For port declaration see Figure 5 and Figure 6. The media compatibility of pressure port 1 and port 2 can be found in “Specification notes”, 7 and 8. Notes: 1. For pressure connections up to 2 bar we recommend a silicone tubing (inner diameter Ø = 2 mm, outer diameter Ø = 6 mm) and above 2 bar PU or PA tubing. Suitable tubing can be found on AMS 5915’s product page. 2. ESD precautions are necessary, it is essential to ground machines and personnel properly during assembly and handling of the device. Sensor type Pressure type to measure Port 1 Port 2 Requirement AMS 5915-xxxx-D differential connected to p1 connected to p2 p1 ≥ p2 positive gage connected to p1 open p1 ≥ pambient negative gage (vacuum) open connected to p2 P2 ≤ pambient AMS 5915-xxxx-D-I differential connected to p1 connected to p2 p1 ≤ p2 positive gage open connected to p2 P2 ≥ pambient negative gage (vacuum) connected to p1 open P1 ≤ pambient AMS 5915-xxxx-D-B differential (bidirectional) connected to p1 connected to p2 p1 ≥ p2 or p1 ≤ p2 AMS 5915-xxxx-A absolute pressure connected to p1 not connected p1 = meas. pressure AMS 5915-xxxx-B barometric pressure connected to p1 not connected p1 = meas. pressure Figure 2: Principle electric circuitry |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |