| Datenblatt-Suchmaschine für elektronische Bauteile |
|
AMS6915 Datenblatt(PDF) 6 Page - Analog Microelectronics GmbH |
|
|
|||||||||||||||||||||||||||||
AMS6915 Datenblatt(HTML) 6 Page - Analog Microelectronics GmbH |
|
6 / 13 page ![]() Board Mount Pressure Sensor AMS 6915 SERIES © 2022, Analog Microelectronics GmbH www.analog-micro.com Datasheet AMS 6915 – Rev. 2.0 6/13 INITIAL OPERATION Electrical Connection The electrical connection of AMS 6915 sensors is typically made by soldering them directly on a printed circuit board or by mounting them on a suitable socket. The basic circuit of the AMS 6915 sensor is shown in Figure 2. To read data from the digital output, it is enough to connect PIN1 (GND), PIN2 (VCC) and the I2C- bus lines to PIN3 (SDA) and PIN4 (SCL). Pins 5 to 8 are internally not connected and can be left unconnected. Important: For I2C-bus communication, each bus line (SCL and SDA) has to be connected to the positive supply voltage (pin Vcc or +3.3 V) via a pull-up resistor. Please add pull- up resistors (4.7 kΩ are recommended) to your bus line if they are not integrated in the I2C-master. Pressure Connection The pressure connection is established by mounting hoses / flexible tubing on the sensor ’s barbed pressure port(s). Depending on the sensor type and the type of measuring pressure, one or two of the pressure ports are connected to the measuring medium / volume, as described in the table below: wherein p1 = pressure at port 1 and p2 = pressure at port 2. For port declaration see Figure 5. The media compatibility of pressure port 1 and port 2 can be found in “Specification notes”, 7 and 8. Notes: 1. For horizontal pressure port configuration Analog Microelectronics recommends a silicone hose tubing with inner diameter Ø = 1.6 mm, outer diameter Ø = 3.2 mm and for vertical pressure port configuration a silicone hose tubing with inner diameter Ø = 2 mm, outer diameter Ø = 6 mm. Suitable tubing can be found on AMS 6915’s product page. 2. ESD precautions are necessary, it is essential to ground machines and personnel properly during assembly and handling of the device. Sensor type Pressure type to measure Port 1 Port 2 Requirement AMS 6915-xxxx-D Differential connected to p1 connected to p2 p1 ≥ p2 positive gage connected to p1 open p1 ≥ pambient negative gage (vacuum) open connected to p2 P2 ≤ pambient AMS 6915-xxxx-D-B differential (bidirectional) connected to p1 connected to p2 p1 ≥ p2 or p1 ≤ p2 AMS 6915-xxxx-G positive gage connected to p1 not available P1 ≥ pambient AMS 6915-xxxx-A absolute pressure not available connected to p2 p2 = meas. Pressure AMS 6915-xxxx-B barometric pressure not available connected to p2 P2 = meas. Pressure Figure 2: Principle electric circuitry |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |