Back Button SI53112-A00AGMR Datasheet HTML 15Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 16Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 17Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 18Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 19Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 20Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 21Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 22Page - Skyworks Solutions Inc. SI53112-A00AGMR Datasheet HTML 23Page - Skyworks Solutions Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 35 page
background image
Si53112
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
19
Rev. 1.1 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 2, 2021
4.2. Block Read/Write
4.2.1. Block Read
After the slave address is sent with the R/W condition bit set, the command byte is sent with the MSB = 0. The
slave acknowledges the register index in the command byte. The master sends a repeat start function. After the
slave acknowledges this, the slave sends the number of bytes it wants to transfer (>0 and <33). The master
acknowledges each byte except the last and sends a stop function.
Figure 10. Block Read Protocol
4.2.2. Block Write
After the slave address is sent with the R/W condition bit not set, the command byte is sent with the MSB = 0. The
lower seven bits indicate the register at which to start the transfer. If the command byte is 00h, the slave device will
be compatible with existing block mode slave devices. The next byte of a write must be the count of bytes that the
master will transfer to the slave device. The byte count must be greater than zero and less than 33. Following this
byte are the data bytes to be transferred to the slave device. The slave device always acknowledges each byte
received. The transfer is terminated after the slave sends the Ack and the master sends a stop function.
Figure 11. Block Write Protocol
Slave
T
Wr
A Command Code
Command
starT
Condition
Block Read Protocol
Acknowledge
repeat starT
Register # to
read
2 x 7 bit = 1
17
1 1
8
Master to
Slave to
Slave
A
Rd
A r
11
7
1
1
Data Byte A Data Byte 0 A Data Byte 1 N P
8
1
81
81 1
Not acknowledge
stoP Condition
Slave Address
T
Wr
A
Command
Command bit
starT
Condition
Block Write Protocol
Acknowledge
Register # to
write
2 x 7 bit = 0
17
1 1
8
Master to
Slave to
A
1
Data Byte 0 A Data Byte 1 A P
18
1
8
1 1
stoP Condition
Byte Count = 2 A
8



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com