| Datenblatt-Suchmaschine für elektronische Bauteile |
|
HTB100-P Datenblatt(PDF) 1 Page - LEM |
|
|
|||||||||||||||||||||||||||||
HTB100-P Datenblatt(HTML) 1 Page - LEM |
|
1 / 2 page ![]() Electrical data Primary continuous Primary current, Type RoHS since direct current measuring range date code (nominal) I PN DC (A) I PM (A) ± 50 ± 150 HTB 50-P, HTB 50-TP1) 46104, 46166 ± 100 ± 300 HTB 100-P, HTB 100-TP1) 45178, 46183 ± 200 ± 500 HTB 200-P 45198 ± 300 ± 600 HTB 300-P 45225 ± 400 ± 600 HTB 400-P 46224 V C Supply voltage (± 5 %) 2) ± 12 .. 15 V I C Current consumption < ± 15 mA V d Rms voltage for AC isolation test, 50 Hz, 1 min 2.5 kV R IS Isolation resistance @ 500 VDC > 500 M Ω V OUT Output voltage (Analog) @ ± I PN DC, RL = 10 kΩ, TA = 25°C ± 4 V R OUT Output internal resistance 100 Ω R L Load resistance ≥ 10 k Ω Accuracy - Dynamic performance data X Accuracy @ I PN DC, TA = 25°C (excluding offset) < ± 1 % of I PN DC ε L Linearity error (0 .. ± I PN DC) < ± 1 % of I PN DC V OE Electrical offset voltage, T A = 25°C < ± 30 mV V OH Hysteresis offset voltage @ I P = 0; after an excursion of 1 x I PN DC < ± 1 % of I PN DC TCV OE Temperature coefficient of V OE HTB 50-(T)P < ± 2.0 mV/K HTB 100-(T)P..400-P < ± 1.0 mV/K TCV OUT Temperature coefficient of V OUT (% of reading) < ± 0.1 %/K t r Response time to 90% of I PN DC < 3 µs BW Frequency bandwidth (0..-3 dB) 3) DC .. 50 kHz General data T A Ambient operating temperature - 20 .. + 80 °C T S Ambient storage temperature - 25 .. + 85 °C m Mass (-TP version) < 30 (< 36) g Standards EN 50178: 1997 2 pins of Ø2mm diameter are available on transducer for PCB soldering. I PN DC = ± 50 .. 400 A Features • Hall effect measuring principle • Galvanic isolation between primary and secondary circuit • Isolationvoltage2500V • Low power consumption • Wide power supply: ±12V to ±15V • Primary bus bar option for 50A and 100A version for ease of connection Advantages • Small size and space saving • Only one design for wide current ratings range • High immunity to external interference. Applications • AC variable speed drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Switched Mode Power Supplies (SMPS) • Power supplies for welding applications. Application domain • Industrial Current Transducers HTB 50..400-P and HTB 50..100-TP For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Notes : 1) -TP version is equipped with a primary bus bar. 2) Operating at ±12V ≤ Vc < ±15V will reduce measuring range. 3) Derating is needed to avoid excessive core heating at high frequency. 070313/11 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/2 |
Ähnliche Teilenummer - HTB100-P |
|
Ähnliche Beschreibung - HTB100-P |
|
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |