| Datenblatt-Suchmaschine für elektronische Bauteile |
|
ACM3P-4-AC1-R-C Datenblatt(PDF) 2 Page - Murata Power Solutions Inc. |
|
|
|||||||||||||||||||||||||||||
ACM3P-4-AC1-R-C Datenblatt(HTML) 2 Page - Murata Power Solutions Inc. |
|
2 / 6 page ![]() Performance/Functional Specifications Typical at TA=+ 25ºC, 120Vac @ 50Hz, unless otherwise noted ORDERING INFORMATION* ACM3P-4-AC1-R-C 100A, 85-264Vac Supply, Red LED Display ACM3P-4-AC1-G-C 100A, 85-264Vac Supply, Green LED Display ACM3P-4-AC1-B-C 100A, 85-264Vac Supply, Blue LED Display ACM3P-4-AC1-B-28-C 100A, 85-264Vac Supply, Blue LED Display, 28 inch lead length TECHNICAL NOTES IMPORTANT! To ensure safe and reliable operation, ACM3P amme- ters must be installed and serviced by qualified technical personnel. Contact Murata Power Solutions if there is any doubt regarding their installation or operation. 1. Measurement Type: ACM3P series 3-phase ammeters employ a precision energy metering integrated circuit and a low-power micro- controller to measure and display the rms value of 2- or 3-phase ac-mains current. However, while the unit has an upper bandwidth of 14kHz, dc components or frequencies below 47Hz will not be measured accurately. 2. Basic Operation: Upon application of ac power to TB1, the unit will first perform a self-test routine and then continuously display am- peres, with one of the three phase-annunciator LEDs illuminated (L1, L2, or L3). The display will remain fixed in one of these reading modes as long as the front panel ‘SEL’ button is not touched. Assuming phase L1 is initially illuminated, momentarily touching the ‘SEL’ button two times in succession will cycle the display to phase L2, and then to phase L3. Momentarily touching ‘SEL’ a third time will return the unit back to displaying phase L1 current. If power is removed and then restored, the ACM3P will perform a self-test and then return to displaying the last selected phase, i.e., the phase it displayed just before power was removed. Configuring for 2-Phase Operation: As shipped, ACM3P ammeters are configured to measure and display 3-phase currents (L1, L2, and L3 current transformers are all active). The unit can be set to display 2-phase currents (only L1 and L2 are active) by performing the follow- ing procedure: A. Press and hold the SEL button for approximately five seconds and then release the button once the words “LinE SEt” appear on the display. B. Briefly tapping the SEL button will alternate the display reading between ‘2-Ph’ and ‘3-Ph’ each time SEL is tapped. C. To change the factory default 3-phase mode to 2-phase, leave the display fixed in the ‘2-Ph’ reading for at least five seconds. To revert the unit back to 3-phase operation simply repeat the above procedure but, in step C, allow the unit to display a fixed ‘3-Ph’ for at least five seconds. ACM3P ammeters with manufacturing date codes of June 2016 or later have the additional ability to continuously scroll (“auto-scroll”) through all 3 phases, or auto-scroll through only 2 phases. The process for configuring the ACM3P for auto-scrolling operation begins by first holding down the ‘SEL’ switch for five seconds to enter the programming mode that is indicated by the display showing “LinE SEt.” After the unit displays “LinE SEt,” immediately and repeatedly pressing and releasing the SEL switch will cycle the unit through the following four operating-mode options: ! Measurement Limits Min. Typ. Max. Units AC (rms) Current, L1, L2, L3 ➀ 0.0 — 100.0 Amperes Overcurrent Rating ➁ 1.5 x Rated full-scale current Performance Sampling Rate 1.5 samples/sec Current Accuracy ➂ ±2% ±3% Measurement Bandwidth (L1, L2, L3) 14kHz Temperature Drift (0 to 65ºC) 0.5 Counts/ºC Zero-Current Reading (within 1 sec.) 1 Counts UL/IEC61010-1 Measurement category II Supply Voltage (TB1) All Models 85 120 264 Vac/47-63Hz Supply Current ➃ ACM3P-X-AC1-R-X-C 35 50 110 mA ACM3P-X-AC1-G-X-C 50 75 165 mA ACM3P-X-AC1-B-X-C 50 75 165 mA Power Supply Terminal Block (TB1) Wire Size 16-22AWG, solid or stranded Insulation Strip Length 6.4mm (0.250 in) Screw Tightening Torque 0.4Nm (3.6 lb-in) Rated Voltage 300Vac Display Display Type and Size 4 Digit LED, 9.14mm (0.36in) high Overrange Indication Flashing display Decimal Point Selection Automatically Set Physical/Environmental Operating Temperature: 0 — +65 ºC Storage Temperature: -40 — +75 ºC Humidity (non-condensing): 0 — 85 % Dimensions: See mechanical specifications Weight, all models 2.6 oz (74g) Notes ➀ Specified full-scale currents are those passing through the power meter’s built-in current transformer’s primary load-circuit. See Notes 2 and 3 below for additional information. ➁ The overcurrent rating of 1.5 x the rated full-scale current is a continuous rating and applies to the current passing through the built in current transformer. Accuracy is guaranteed up to the rated current level. ➂ Power Meters are calibrated with near full-scale 50Hz sine-wave inputs. ➃ All specified maximum supply currents are steady state. Larger surge currents can occur at initial application of line power. continued on next page www.murata.com-ps/support ACM3P Series Three-Phase AC Ammeters MPM_ACM3P Series.C02 Page 2 of 6 *See http://www.murata.com/products/power for model-specific availability. |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |