| Datenblatt-Suchmaschine für elektronische Bauteile |
|
CS650CS655 Datenblatt(PDF) 2 Page - Campbell Scientific United Kingdom |
|
|
|||||||||||||||||||||||||||||
CS650CS655 Datenblatt(HTML) 2 Page - Campbell Scientific United Kingdom |
|
2 / 3 page ![]() 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sales@campbellsci.co.uk | www.campbellsci.eu UK | AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | SE ASIA | SOUTH AFRICA | SPAIN | USA © 2012 Campbell Scientific March 14, 2017 Specifications Sensing Volume1: CS650: 7800 cm3 CS655: 3600 cm3 (~7.5 cm radius around each probe rod and 4.5 cm beyond the end of the rods) Ingress Protection Rating: IP68 Soil Temperature Measurement Range: -10° to +70°C Accuracy2: ±0.5°C for probe body buried in soil Precision3: ±0.02°C Electrical Conductivity Measurements Range: CS650 CS655 Solution EC 0 to 3 dS/m 0 to 8 dS/m Bulk EC 0 to 3 dS/m 0 to 8 dS/m Accuracy2: ±(5% of reading + 0.05 dS/m) Precision3: 0.5% of BEC Relative Dielectric Permittivity Measurements Range: 1 to 81 Accuracy2 CS650 CS655 1 to 40 Range ±(2% of reading + 0.6) for solution EC ≤3 dS/m ±(3% of reading + 0.8) for solution EC ≤8 dS/m 40 to 81 Range ±1.4 for solution EC ≤1 dS/m ±2 for solution EC ≤2.8 dS/m Precision3: <0.02 Volumetric Water Content Measurements Range: 5% to 50% Accuracy2: CS650: ±3% typical in mineral soils,where solution EC ≤3 dS/m CS655: ±3% typical in mineral soils,where solution EC ≤10 dS/m Precision3: <0.05% 1 Approximately 7.5 cm radius around each probe rod and 4.5 cm beyond the end of the rods. 2 Accuracy specifications are based on laboratory measurements in a series of solutions with dielectric permittivities ranging from 1 to 81 and solution electrical conductivities ranging from 0 to 3 dS/m. 3 Precision describes the repeatability of a measurement. It is determined for the CS650/CS655 by taking repeated measurements in the same material. Electrical Sensor Output: SDI-12; serial RS-232 Warmup Time: 3 s Measurement Time: 3 ms to measure; 600 ms to complete SDI-12 command Power Supply Requirements: 6V DC to 18V DC; must be able to supply 45 mA @ 12V DC Current Drain Active (3 ms): 45 mA typical @ 12V DC (80 mA @ 6V DC, 35 mA @ 18V DC) Quiescent: 135 μA @ 12V DC Average: I = 0.09n + [3.5 + 0.024(n-1)]n/s Where, I = average current in milliamps n = number of CS650/CS655 probes s = number of seconds between measurement Electromagnetic: CE compliant (EMC compliant performance criteria available upon request). Meets EN61326 requirements for protection against electrostatic discharge and surge. External RF sources can affect the probe’s operation. Therefore, the probe should be located away from significant sources of RF such as ac power lines and motors. Interprobe Interference: Probes enabled simultaneously and within ~9 in. of each other can cause erratic measurements. If the probes must be installed within 9 in. of each other, configure the SDI-12 communication such that the probes are not enabled simultaneously. Physical Operational Temperature: -10° to + 70°C Maximum Cable Length: 610 m (2000 ft) combined length for up to 10 sensors connected to the same datalogger control port. Rod Dimensions Length: CS650 - 300 mm (11.8 in) CS655 - 120 mm (4.72 in.) Diameter: 3.2 mm (0.13 in.) Spacing: 32 mm (1.3 in.) Probe Head Dimensions Height: 85 mm (3.3 in.) Width: 63 mm (2.5 in.) Depth: 18 mm (0.7 in.) Weight Probe without cable: CS650 - 280 g (9.9 oz) CS655 - 240 g (8.46 oz.) Cable: 35 g per m (0.38 oz. per ft) The CS650G makes inserting soil-water sensors easier in dense or rocky soils. This tool can be hammered into the soil with force that might damage the sensor if the CS650G were not used. It makes pilot holes into which the rods of the sensors can then be inserted. It replaces both the 14383 and 14384. CS650G Rod Insertion Guide Tool |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |