LM3532 Datenblatt(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LM3532 Datenblatt(HTML) 21 Page - Texas Instruments |
|
21 / 52 page ![]() VALS_ Enable ALS 1 2V 2 3 4 5 6 7 Zone 4 Zone 3 Zone 2 Zone 1 Zone 0 Current Average Zone 4 *Note:it takes a full average period to generate an averager output value 3 3 2 1 8 9 10 11 12 2 3 3 3 4 4 4 ILED 4 Zone 4 Brightness Target Averager Ouput 4 3 3 2 1 2 3 3 3 4 4 4 4 0 ALS Fast Start-Up 13 Average Period # LED Current Run Time Ramp Down Zone 3 Brightness Target Zone 2 Brightness Target Zone 1 Brightness Target Zone 4 Brightness Target LED Current Run Time Ramp Up 4 LM3532 www.ti.com SNVS653E – JULY 2011 – REVISED AUGUST 2015 13. The 12th average period the ALS voltage averages to Zone 4. The Averager Output remains at Zone 4. 14. The 13th average period the ALS voltage averages to Zone 4. The Averager Output remains at Zone 4. Because this is the 3rd average period that the Averager Output has shown a change in the increasing direction from the initial Zone 3, the backlight current is forced to change to the current Averager Output (Zone 4's) target current. Figure 19. Direct ALS Control 7.4.11 Down Delay The down-delay algorithm uses all the same rules from the ALS Rules section, except it provides for adding additional average period delays required for decreasing transitions of the Averager Output, before the LED current is programmed to a lower zone target current. The additional average period delays are programmed via the ALS Down-Delay register. The register provides 32 settings for increasing the down delay from 3 extra (code 00000) up to 34 extra (code 11111). For example, if the down-delay algorithm is enabled, and the ALS Down- Delay register were programmed with 0x00 (3 extra delays), then the Averager Output would need to see 6 consecutive changes in decreasing Zones (or 6 consecutive average periods that changed and remained lower), before the backlight current was programmed to the lower zones target current. Referring to Figure 20, assume that Down Delay is enabled and the ALS Down-Delay register is programmed with 0x02 (5 extra delays, 8 average period total delay for downward changes in the backlight target current): 1. When the ALS is enabled the ALS fast start-up (1.1 ms average period) quickly brings the Averager Output to the correct zone. This takes 3 fast average periods or approximately 3.3 ms. 2. The first average period the ALS averages to Zone 3. Copyright © 2011–2015, Texas Instruments Incorporated Submit Documentation Feedback 21 Product Folder Links: LM3532 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |