3 / 14 page ![]() www.sensirion.com Version 0.8 – January 2017 3/14 2. Specifications 2.1 Electrical Specifications Parameter Symbol Condition Min. Typ. Max. Units Comments Supply Voltage VDD 3.0 3.3 4 V For 5V supply contact Sensirion Power-up/down level VPOR 2.3 2.5 2.7 V VDD ramp up slew VDD, ramp 0.2 V/ms Minimum voltage ramp up slew when powering up SDP3x Supply current IDD Measuring 3.8 5.5 mA Idle state 1.1 mA IRQn driving strength 4 mA 2.2 Timing Specifications Parameter Symbol Condition Min. Typ. Max. Units Comments Power-up time tPU 25 ms Time to sensor ready Soft reset time tSR 20 ms Time between soft reset command and sensor ready I2C SCL frequency fI2C 400 1000 kHz Update rate differential pressure value Continuous mode 900 1000 1100 Hz Upgrade to 2kHz expected in March 2017 Update rate temperature value Continuous mode 112.5 125 137.5 Hz Temperature value is updated once every eight pressure values Measurement time Triggered mode 40 45 50 ms 2.3 Mechanical Specifications Parameter Symbol Condition Min. Typ. Max. Units Comments Allowable overpressure1 Pmax 1 bar Rated burst pressure Pburst 3 bar Weight W 0.2 g 2.4 Materials Parameter Wetted materials Glass (silicon nitride, silicon oxide), LCP, green epoxy-based mold compound, epoxy-based resins REACH, RoHS REACH and RoHS compliant 2.5 Absolute Maximum Ratings Parameter Rating Units Supply Voltage VDD -0.3 to 4.5 V Max Voltage on pins SDA, SCL, IRQn -0.3 to VDD+0.3 V Input current on any pin ±70 mA Operating temperature range2 -40 to +85 °C Storage temperature range3 -40 to +85 °C Max. humidity for long term exposure 40°C dew point ESD HBM (human body model) 2 kV 1 Allowable overpressure during operation. Refer to the SDP selection guide for pressure dependency of the measured signal. Fast absolute pressure changes on both ports can result in dynamic effects on the sensor signal. For higher overpressures or continuous high overpressures contact Sensirion. 2 For Air and N2. Long term exposure to high temperatures and (high concentrations of) O2 can reduce the product lifetime 3 For long term storage in Tape and Reel, please refer to the SDP3x handling instructions |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |