34 / 63 page ![]() V9-T1-34 Volume 9—OEM—Original Equipment Manufacturer CA08100011E—February 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1 Circuit Protection Circuit Breakers Catalog Number Selection Series NRX Power Breakers (Exclusionary Rules Apply) Note 1 Contact Eaton for available voltages. Not all voltages are currently available. Breaker Frame Size N = Type NF, 630–1600A, (70 mm pole spacing) Standard, Mechanism, Device S = UL 1066, stored energy, power breaker X = UL 489, stored energy, insulated case breaker E = IEC 60947-2, stored energy, air breaker Fault Current Rating S4 = 42 kA at 480 Vac UL or 415 Vac IEC S5 = 50 kA at 480 Vac UL or 415 Vac IEC S6 = 65 kA at 480 Vac UL or 415 Vac IEC Frame Rating (Amperes) 07 = 630 (IEC only) 08 = 800 10 = 1000 (IEC only) 12 = 1200 (UL only) 13 = 1250 (IEC only) 16 = 1600 (On NF: IEC only) Poles, Phasing 3 = Three-pole, ABC 4 = Four-pole, NABC Mounting Configuration W = Drawout B = Fixed mount rear connect, mounting bracket, with secondary terminal row R = Fixed mount rear connect, surface mount, with secondary terminal row T = Fixed mount front connect, surface mount, cable connect, with secondary terminal row F = Fixed mount front connect, mounting bracket, bus connect, with secondary terminal row S = Fixed mount front connect, surface mount, bus connect, with secondary terminal row Trip Unit 52 = 520 LSI, no ZSI 53 = 520 LSI, with ZSI 5G = 520 LSIG, no ZSI 5H = 520 LSIG, with ZSI M2 = 520M LSI, no ZSI, 24 Vdc M3 = 520M LSI, with ZSI, 24 Vdc MA = 520M LSIA, no ZSI, 24 Vdc MB = 520M LSIA, with ZSI, 24 Vdc MG = 520M LSIG, no ZSI, 24 Vdc MH = 520M LSIG, with ZSI, 24 Vdc R2 = 520M LSI, no ZSI, 24 Vdc, with Arcflash Reduction Maintenance System™ R3 = 520M LSI, with ZSI, 24 Vdc, with Arcflash Reduction Maintenance System RA = 520M LSIA, no ZSI, 24 Vdc, with Arcflash Reduction Maintenance System RB = 520M LSIA, with ZSI, 24 Vdc, with Arcflash Reduction Maintenance System RG = 520M LSIG, no ZSI, 24 Vdc, with Arcflash Reduction Maintenance System RH = 520M LSIG, with ZSI, 24 Vdc, with Arcflash Reduction Maintenance System SW = Non-auto switch Rating Plug (Amperes) 1 = 200 2 = 250 3 = 300 4 = 400 5 = 500 6 = 600 7 = 630 8 = 800 A = 1000 B = 1200 C = 1250 D = 1600 Shunt Trip 1 N = No shunt trip A = 110–127 Vac/Vdc R = 208–240 Vac/Vdc L = 24 Vdc H = 48 Vdc Motor Operator 1 M = Manually operated B = 110–125 Vac W = 110–125 Vdc T = 208–250 Vac P = 220–250 Vdc L = 24 Vdc H = 48 Vdc Spring Release, Latch Check Switch 1 N = No spring release, no LCS A = 110–127 Vac/Vdc, no LCS R = 208–240 Vac/Vdc, no LCS N S S6 08 3 W 52 8 A B A N 4 X N D X UVR, Second Shunt Trip 1 N = None A = 110–125 Vac/Vdc UVR R = 220–250 Vac/Vdc UVR 1 = 110–127 Vac/Vdc second shunt trip 2 = 208–240 Vac/Vdc second shunt trip Auxiliary, Switches, Label Language 1 E = No auxiliary switches, no label (parent) 2 = 2 Form C, English 4 = 4 Form C, English Trip Indicator and Bell Alarm/OTS, Secondary Terminal Blocks 1 N = No indicator, no OTS, secondary terminal blocks per breaker options X = Trip indicator provided, no OTS, secondary terminal blocks per breaker options Z = Trip indicator provided, 2 Form C OTS, secondary terminal blocks per breaker options M = Interlock trip indicator provided, no OTS, secondary terminal blocks per breaker options Y = Trip indicator provided, 2 Form C OTS, secondary terminal blocks per breaker options 1 = No indicator, no OTS, full complement secondary terminal blocks 2 = Trip indicator, no OTS, full complement secondary terminal blocks 3 = Trip indicator provided, 2 Form C OTS, full complement secondary terminal blocks 4 = Interlock trip indicator provided, no OTS, full complement secondary terminal blocks 5 = Interlock trip indicator provided, 2 Form C, full complement secondary terminal blocks Future Use X = All product Drawout Breaker Shipping, Fixed Breaker Terminals, Door Frame Kit D = Drawout (or parent) breaker shipping alone, without door frame kit C = Drawout breaker in cassette, no shutters, no terminals, with door frame kit K = Fixed breaker, no adapters, rear connector, with door frame kit, with mounting feet, with door frame kit A = Terminal adapters for rear connect, short vertical/horizontal, with door frame kit E = Terminal adapters for rear connect, long vertical/horizontal, with door frame kit F = Terminal adapters for rear connect, with mounting feet, short vertical/horizontal, with door frame kit H = Terminal adapters for rear connect, with mounting feet, long vertical/horizontal, with door frame kit 1 = Drawout breaker in cassette, no shutters, short vertical/horizontal, with door frame kit 2 = Drawout breaker in cassette, no shutters, long vertical/horizontal, with door frame kit 4 = Drawout breaker in cassette, with shutters, short vertical/horizontal, with door frame kit 5 = Drawout breaker in cassette, with shutters, long vertical/horizontal, with door frame kit 9 = Drawout breaker in cassette, with shutters, no terminals, with door frame kit Padlock Provisions, Key Lock Provisions, Operations Counter 1 N = No PB covers, none, no counter |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |