PX3EF1BH300PA Datenblatt(PDF) 4 Page - Honeywell Solid State Electronics Center

Teilenummer PX3EF1BH300PA
Bauteilbeschribung  Heavy Duty Pressure Transducers
PDF  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Hersteller  HONEYWELL [Honeywell Solid State Electronics Center]
Direct Link  http://honeywell.com/Pages/Home.aspx
Logo HONEYWELL - Honeywell Solid State Electronics Center

PX3EF1BH300PA Datenblatt(HTML) 4 Page - Honeywell Solid State Electronics Center

  PX3EF1BH300PA Datasheet HTML 1Page - Honeywell Solid State Electronics Center PX3EF1BH300PA Datasheet HTML 2Page - Honeywell Solid State Electronics Center PX3EF1BH300PA Datasheet HTML 3Page - Honeywell Solid State Electronics Center PX3EF1BH300PA Datasheet HTML 4Page - Honeywell Solid State Electronics Center PX3EF1BH300PA Datasheet HTML 5Page - Honeywell Solid State Electronics Center PX3EF1BH300PA Datasheet HTML 6Page - Honeywell Solid State Electronics Center PX3EF1BH300PA Datasheet HTML 7Page - Honeywell Solid State Electronics Center PX3EF1BH300PA Datasheet HTML 8Page - Honeywell Solid State Electronics Center  
Zoom Inzoom in Zoom Outzoom out
 4 / 8 page
background image
4
Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Table 6. Environmental and Mechanical Specifications
Characteristic
Parameter
Shock:
threaded ports
tube port
100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C [77°F])
100 G per MIL-STD-202F, Method 213B, and Condition C
Vibration:
threaded ports
tube port
20 G sweep, 10 Hz to 2000 Hz (at 25°C [77°F])
10 Hz to 55 Hz, 2 mm displacement, tested as per IEC 60068-2-6; Test FC. (at 25°C [77°F])
Ingress protection:
Metri-Pack 150 electrical connector
cable harness electrical connector
IP67
IP69K
Ambient humidity
0 %RH to 95 %RH, non-condensing
External freeze/thaw resistance
>6 cycles from -30°C to 50°C [-22°F to 122°F]
Wetted materials:
threaded ports
tube port
braze filler
internal O-ring media seal
sensing element and substrate
adhesives
brass C36000; lead (Pb) content: 3.7% max.
copper UNS C12200; lead (Pb) free
silver and copper alloy
sealmaterialasrequiredbytheapplication(seesealmaterialmediacompatibilityoptionsbelow)
alumina, glass, silicon
epoxy
InternalO-ringmaterialmediacompatibility1:
HNBR (option H)
silicone (option S)
refrigerants, engine oil, petroleum-based hydraulic fluid
dry air
Other materials:
Metri-Pack 150 electrical connector
external O-ring seal on G1, M1 ports
PBT 30% GF
nitrile (-30°C to 125°C [-22°F to 257°F])
1
Honeywell can assist with selecting suitable O-ring seal material for the media based on the seal manufacturer’s recommendation.
The customer should test the compatibility with the media to ensure that it is correct for the application.
CAUTION
PRODUCT DAMAGE DUE TO MECHANICAL ISSUES
• Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating
materials and thread sealants can result in significantly different torque values from one application to the next.)
• When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling.
Ensure the sealant is rated for the application.
• Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.
• Always hand-start transducers into the hole to prevent cross threading and damage.
• Ensure that torque is not applied to the electrical connector.
• Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged
seals can compromise ingress protection, leading to short circuits.
Failure to comply with these instructions may result in product damage.
CAUTION
PRODUCT DAMAGE TO TUBE PRESSURE PORT TYPE DURING BRAZING
Ensure that the temperature of the brass port and plastic connector is maintained below 125°C during flame brazing.
Exposure to temperatures higher than 125°C can cause permanent product damage and can compromise ingress protection
leading to short circuits.
Failure to comply with these instructions may result in product damage.
CAUTION
PRODUCT DAMAGE DUE TO PARTICULATES
• Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity. All
PX3 Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect sensor output.
• It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less
likely to enter and settle within the pressure transducer if it is in this position.
• Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output;
rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue.
Failure to comply with these instructions may result in product damage.



Html Pages

1 2 3 4 5 6 7 8


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com