13 / 17 page ![]() Preliminary Technical Data AD7357 Rev. PrD | Page 13 of 17 MODES OF OPERATION The mode of operation of the AD7357 is selected by controlling the (logic) state of the CS signal during a conversion. There are three possible modes of operation: normal mode, partial power- down mode and full power-down mode. After a conversion has been initiated, the point at which CS is pulled high determines which power-down mode, if any, the device enters. Similarly, if already in a power-down mode, CS can control whether the device returns to normal operation or remains in power-down. These modes of operation are designed to provide flexible power management options. These options can be chosen to optimize the power dissipation/throughput rate ratio for the differing application requirements. NORMAL MODE This mode is intended for applications needing fastest throughput rates since the user does not have to worry about any power-up times with the AD7357 remaining fully powered at all times. Figure 14 shows the general diagram of the operation of the AD7357 in this mode. SCLK LEADING ZEROS + CONVERSION RESULT CS DOUTA DOUTB 114 10 Figure 14. Normal Mode Operation The conversion is initiated on the falling edge of CS, as described in the Serial Interface section. To ensure that the part remains fully powered up at all times, CS must remain low until at least 10 SCLK falling edges have elapsed after the falling edge of CS. If CS is brought high any time after the 10th SCLK falling edge but before the 16th SCLK falling edge, the part remains powered up, but the conversion is terminated and SDATAA and SDATAB go back into three-state. 16 serial clock cycles are required to complete the conversion and access the conversion result for the AD7357. The SDATA lines do not return to three- state after 16 SCLK cycles have elapsed, but instead do so when CS is brought high again. If CS is left low for another 2 SCLK cycles, two trailing zeros are clocked out after the data. If CS is left low for a further 16 SCLK cycles, the result for the other ADC on board is also accessed on the same SDATA line as shown in Figure 20 (see the Serial Interface section). Once 32 SCLK cycles have elapsed, the SDATA line returns to three-state on the 32nd SCLK falling edge. If CS is brought high prior to this, the SDATA line returns to three-state at that point. Thus, CS may idle low after 32 SCLK cycles until it is brought high again sometime prior to the next conversion if so desired, since the bus still returns to three-state upon completion of the dual result read. Once a data transfer is complete and SDATAA and SDATAB have returned to three-state, another conversion can be initiated after the quiet time, tQUIET, has elapsed by bringing CS low again (assuming the required acquisition time has been allowed). PARTIAL POWER-DOWN MODE This mode is intended for use in applications where slower throughput rates are required. Either the ADC is powered down between each conversion, or a series of conversions may be performed at a high throughput rate and the ADC is then powered down for a relatively long duration between these bursts of several conversions. When the AD7357 is in partial power-down, all analog circuitry is powered down except for the on-chip reference and reference buffers. To enter partial power, the conversion process must be interrupted by bringing CS high anywhere after the 2nd falling edge of SCLK and before the 10th falling edge of SCLK, as shown in Figure 15. Once CS has been brought high in this window of SCLKs, the part enters partial power-down, the conversion that was initiated by the falling edge of CS is terminated, and SDATAA and SDATAB go back into three-state. If CS is brought high before the 2nd SCLK falling edge, the part remains in normal mode and does not power down. This avoids accidental power-down due to glitches on the CS line. SCLK THREE-STATE CS DOUTA DOUTB 114 10 2 Figure 15. Entering Partial Power-Down Mode To exit this mode of operation and power up the AD7357 again, a dummy conversion is performed. On the falling of CS, the device begins to power up, and continues to power up as long as CS is held low until after the falling edge of the 10th SCLK. The device is fully powered up after approximately TBD μs has elapsed, and valid data results from the next conversion, as shown in Figure 16. If CS is brought high before the 2nd falling edge of SCLK, the AD7357 again goes into partial power-down. This avoids accidental power-up due to glitches on the CS line. Although the device may begin to power up on the falling edge of CS, it powers down again on the rising edge of CS. If the AD7357 is already in partial power-down mode and CS is brought high between the 2nd and 10th falling edges of SCLK, the device enters full power-down mode. FULL POWER-DOWN MODE This mode is intended for use in applications where throughput rates slower than those in the partial power-down mode are required, as power-up from a full power-down takes substantially longer than that from a partial power-down. This |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |