| Datenblatt-Suchmaschine für elektronische Bauteile |
|
1908 Datenblatt(PDF) 2 Page - Thurlby Thandar Instruments Ltd. |
|
|
|||||||||||||||||||||||||||||
1908 Datenblatt(HTML) 2 Page - Thurlby Thandar Instruments Ltd. |
|
2 / 4 page ![]() 1908 and 1908P 5½ digit bench/portable multimeters Internal rechargeable batteries for ‘use anywhere’ versatility Unlike most high performance bench multimeters, the 1908 and 1908P can operate without AC power whenever required. The batteries are charged from the internal power supply and can give up to 35 hours of operation. This enables the meter to be used in locations where no AC line power is available, or moved around multiple room locations without the nuisance of having to find a power socket. When precision measurements are needed, handheld portable multimeters may not be up to the task. The 1908/1908P not only offers fully portable precision, but also built-in data logging for remote locations. Key Features f Dual display and dual measurement capability f Internal rechargeable batteries for true portability f High accuracy and resolution: 0.02%, 1nA, 1mW, 100nA f Frequency, capacitance and temperature measurements f Wide range of maths and data logging functions f 2 or 4 terminal ohms measurement f Wide true RMS AC; AC + DC measurements f Software for remote control and logging included f USB, RS232, GPIB* and LAN (LXI) interfaces** ** RS232, GPIB and LAN interfaces on 1908P only.* GPIB optional. Two models - 1908 and 1908P The 1908 multimeter incorporates a USB interface for remote control and readback. The 1908P incorporates USB, RS232 and LXI compliant LAN interfaces making it suitable for a wider range of system applications. GPIB can be added as an option. Both models can operate from either AC-line power or internal batteries, but the 1908P requires AC-line power when using the remote interfaces.* *USB does not require AC line power on either model Dual display and dual measurement system The 1908 has both a main display and a secondary display. The two displays can be used for a variety of purposes: z To display a measurement together with the selected range (e.g. 100 Vdc). z To display a measurement in two different units (e.g. ac volts and dBm). z To display the result of a calculated function (e.g. value and % deviation). z To measure and display two parameters of one signal (e.g. ac and dc volts). z To measure and display two different signals (e.g. ac volts and dc current). Capabilities in detail affordable, portable precision Dual measurement/display combinations Primary Display Secondary Display Choices DCV ACV DCI* ACI* ACV DCV ACI* DCI* Hz ACV +DCV ACV DCV Hz DCI ACI DCV* ACV* ACI DCI ACV* DCV* Hz ACI + DCI ACI DCI Hz dB ACV DCV Hz ACI* DCI* * requires multi-lead connection Automatic or Manual ranging Quick response auto-ranging is provided for all measurement parameters ensuring the best possible resolution at all times. Alternatively manual ranging can be selected. The secondary display can show the range value, giving greater clarity. Wideband True RMS AC True RMS AC gives accurate measurements regardless of the waveform shape. The wide bandwidth attenuator provides high accuracy within the audio band and gives extended response to avoid errors when measuring switching waveforms. Measurements are normally AC coupled but, when required, the true RMS value of the AC plus DC components can be shown. Frequency & Capacitance High accuracy frequency measurement (better than 0.01%) is available from 10Hz to 120kHz. A reciprocal counting technique is used to give up to 0.01Hz resolution and fast update. Capacitance measurement is also built-in with five ranges up to 120μF. Temperature Measurement Linearised measurement is incorporated for PT100 and PT1000 platinum resistance temperature detectors (RTDs). It can use either a 2 wire or 4 wire connection and can be displayed in °C or °F. Smart functions for added power Linear scaling with offset This function enables a reading to be multiplied by a scale factor (A) and for an offset (b) to be added or subtracted. This means, for example, that the electrical output of a transducer can be scaled to give a direct readout of the physical parameter e.g. temperature or weight. It is particularly useful with 4-20mA current loops. dB measurements AC voltages can be displayed in dB as well as voltage. Built-in zero reference scaling enables voltages to be displayed in dBm relative to a choice of impedance from 50W up to 8kW. The voltage can be displayed simultaneously in the secondary display. Limits comparison This function enables the reading to be tested against high and low limits set by the user. The display then shows HI, LO or PASS in addition to the measurement result. NOTE: the display illustrations on this page are actual size when printed at A4. |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |