60 / 101 page ![]() ST7SCR 60/101 SMARTCARD INTERFACE (Cont’d) Waiting Time Counter The Waiting Time counter is a 24-bit counter used to generate a timeout signal. The elementary time unit counter acts as a pres- caler to the Waiting Time counter which is incre- mented at the etu rate. The Waiting Time Counter can be used in both UART mode and Manual mode and acts in differ- ent ways depending on the selected mode. The CRDWT2, CRDWT1 and CRDWT0 are load registers only, the counter itself is not directly ac- cessible. UART Mode The load conditions are either: – A Start bit is detected while UART bit =1 and the WTEN bit =1. or – A write access to the CRDWT2 register is per- formed while the UART bit = 1 and the WTEN bit = 0. In this case, the Waiting Time counter can be used as a general purpose timer. In UART mode, if the WTEN bit of the CRDCR reg- ister is set, the counter is loaded automatically on start bit detection. Software can change the time out value on-the-fly by writing to the CRDWT registers. For example, in T=1 mode, software must load the Block Waiting Time (BWT) time-out in the CRDWT registers before the start bit of the last transmitted character. Then, after transmission of this last character, sig- nalled by the TXC interrupt, software must write the CWT value (Character Waiting Time) in the CRDWT registers. See example in Figure 33. Manual mode The load conditions are: – A write access to the CRDWT2 register is per- formed while the UART bit = 0 and the WTEN bit = 0 In Manual mode, if the WTEN bit of the CRDCR register is reset, the timer acts as a general pur- pose timer. The timer is loaded when a write ac- cess to the CRDWT2 register occurs. The timer starts when the WTEN bit = 1. 12.4.3.4 Interrupt generator The Smartcard Interface has 2 interrupt vectors: – Card Insertion/Removal Interrupt – CRD Interrupt The CRD interrupt is cleared when software reads the CRDIPR register. The Card Insertion/Removal is an external interrupt and is cleared automatical- ly by hardware at the end of the interrupt service routine (IRET instruction). If an interrupt occurs while the CRDIPR register is being read, the corresponding bit will be set by hardware after the read access is done. Figure 33. Waiting Time Counter Example BWT CWT Reader Smartcard Firmware must program BWT Firmware must program CWT TXC Interrupt Start bit Waiting Time Counter loaded on start bit CHAR0 CHAR1 CHARn CHAR0 CHAR1 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |